User Manual

Operating Instructions Type 6017
Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function A).
Seal Materials and Fluids handled:
See Table 1.
Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 194 °F (90 °C)
The UL-listed valve for Hazardous Locations is suitable for the
fluids air, inert gas, water and gasoline.
For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature 104 °F (40 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Intrinsically Safe Apparatus for use in Class I, II and III,
Division 1 Hazardous Locations (T6 rated)
Max. Ambient Temperature 140 °F (60 °C)
Max. Fluid Temperature 140 °F (60 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table 1.
Pressure Range:
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal shavings, pipe sealing materials, welding scale
etc.). Installation as required but preferable with coil uppermost.
Installation in this position tends to prevent foreign matter
remaining in core tube (increased life). Do not put any loads on
coil unit.
PTFE tape is recommended for sealing ports. Mounting is
accomplished by means of four M4 x 8 mm tapped holes
located on the valve underside. Letters on valve body indicate
pressure por t, exhaust and outlet of the valve.
Marking (example):
Body Material
BR = Brass
SS = Stainless Steel
Seal Material
EPDM = EPDM
NBR = NBR
FKM = FKM
Circuit function
A = Normally Closed
Item No.
Voltage / Frequency / Power Consumption
Maximum Pressure
Approvals
The valve is either approved as
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temper ature T 4
or
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temper ature T 6
or
Intrinsically Safe Apparatus for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1
Operating Temper ature T 6
or
FM approved as
Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temper ature T 4
UL listed for General Purpose
CSA approved for General Purpose
See label on the valve.
Table 1 Seal Materials Seat / O-ring
Fluid Temperatures [°F] Buna “N” Ethylene FKM
NBR Propylene (EPDM)
Air Fluid Temp. + 14 to + 194 - 40 to + 266 + 14 to + 266
Ambient + 14 to + 130 + 14 to + 130 + 14 to + 130
Water Fluid Temp. + 32 to + 194 + 32 to + 212 + 32 to + 212
Ambient + 32 to + 130 + 32 to + 130 + 32 to +130
Neutral gas Fluid Temp. + 14 to + 194 - 40 to + 266 + 14 to + 266
Ambient + 14 to + 130 + 14 to + 130 + 14 to + 130
Light oil Fluid Temp. + 14 to + 194 + 14 to + 266
Ambient + 14 to + 130 + 14 to + 130
Operating Instructions 0605/09_EN-EN_00800026
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only

Summary of content (2 pages)