User guide

14
Technical data
Type 8025 / 8035
6.3. General data
Pipe diameter
8025 flowmeter
8025 transmitter (remote versions)
8035 flowmeter
DN20 (except for the DN specified p.22) to DN400
DN06 to DN400
DN06 to DN65
Type of fitting S020, for a compact 8025
S030, for a 8035
Type of fluid liquid
viscosity: max. 300 cSt
rate of solid particles: max. 1%
Fluid temperature (compact versions)
with fitting in PVC
with fitting in PP
with fitting in PVDF, stainless steel or brass
The fluid temperature may be restricted by the fluid pressure, the
material the flow sensor is made of and the material the S020 or
S030 fitting used is made of. See "Fig. 2" and "Fig. 3".
0 to +50 °C
0 to +80 °C
-15 to +80 °C
Fluid pressure (compact versions)
8025 compact
8035 with S030 fitting in plastic
8035 with S030 fitting in metal
The fluid pressure may be restricted by the fluid temperature, the
material the flow sensor is made of (only for the compact 8025) and
the material the fitting used is made of. See "Fig. 2" and "Fig. 3".
PN10
PN10
PN16 (PN40 on request)
Flow rate measurement
Measurement range
- Sensor with pulse output (Hall)
- Sensor with sinus output (coil)
Accuracy
- with a teach-in procedure
- with the K factor of the fitting used
Linearity
1)
Repeatability
1)
- 0.3 m/s to 10 m/s
- 0.5 m/s to 10 m/s
- 1 % of the measured value (at the value of the teach-in flow
rate)
- 2,5 % of the measured value
±0.5 % of the full scale
±0,4 % of the measured value
1)
Determined in the following reference conditions: medium = water, water and ambient temperatures 20 °C, min. upstream and downstream
distances respected, appropriate pipe dimensions
English