Manual

28
12-36 V DC
+ -
+-
1
3
2
V+
0 V DC
Power supply
Pulse input on external instrument
Terminal block of the 2508
Fig. 5: NPN wiring of the Hall version
Terminal block of the 2508
12-36 V DC
+-
1
3
2
V+
0 V DC
+-
Pulse input on external instrument
Power supply
Fig. 6: PNP wiring of the Hall version
English
29
1: V+ (12-36 V DC)
2: NPN transistor output
3: 0 V DC
4: not connected
Fig. 7: Pin assignment of the fixed connector, Hall Low
Power version
+ -
IN
1
3
2
Remote transmitter
IN = pulse input on remote transmitter
Terminal block of the 2508
Fig. 8: NPN wiring of the Hall Low Power version
English
29
30
8. MAINTENANCE
Safety instructions
danger
Risk of injury due to electrical voltage.
Shut down and isolate the electrical power source
before carrying out work on the system.
Observe all applicable accident protection and safety
regulations for electrical equipment.
Risk of injury due to high pressure in the installation.
Stop the circulation of fluid, cut off the pressure
and drain the pipe before loosening the process
connections.
Risk of injury due to high fluid temperatures.
Use safety gloves to handle the device.
Stop the circulation of fluid and drain the pipes before
loosening the process connections.
Keep all easily flammable material and fluid away from
the device.
English
31
danger
Risk of injury due to the nature of the fluid.
Respect the prevailing regulations on accident preven-
tion and safety relating to the use of aggressive fluids.
Warning
Risk of injury due to non-conforming maintenance.
Maintenance must only be carried out by qualified and
skilled staff with the appropriate tools.
Ensure that the restart of the installation is controlled
after any interventions.
Cleaning
note
The device may be damaged by the cleaning liquid.
Clean the device with a cloth slightly dampened with
water or a cleaning liquid compatible with the materials
the device is made of.
English
31