User Manual

7.2.2. Installation of 8025 on the S020
fitting
Insert nut 3 on the fitting 5.
Insert the snap ring 2 into the groove 4.
Check that seal 6 is correctly inserted on the
flow sensor.
Slowly insert the device 1 into the fitting.
If the mounting is correctly done the device cannot
turn around anymore.
Hand lock the assembly with the nut 3.
2
1
3
4
5
6
Fig. 7: Installation of 8025 on the S020 fitting
7.2.3. Installation of the SE35 electronic
module on the S030 fitting-sensor
Insert the electronic module 2 in the
S030 fitting-sensor.
Secure with a 30° clockwise rotation.
Tighten the lateral screw 3 to lock
the electronic module with the
fitting-sensor.
1
2
3
Fig. 8: Installation of the SE35 electronic module on the S030
fitting-sensor
7.3. Description of the electronic
board connections
Terminal block:
+ : positive supply (red wire)
- : negative supply (black wire)
Connector : branchement du
capteur de débit
Terminal block
Connector
OFF ON
Fig. 9: Electronic board
connections
14
Installation
Type 8025/8035 battery powered
English