User Manual

8.6.4. Configuring the filter
This parameter makes it possible to dampen the fluctuations ot the
display.
Ten filters are available.
FiltER FiltER 0
tOtAl
Choose the filter.
Confirm
FiltER 9
0......9
Fig. 20: Diagram of the "FILTER" parameter of the Configuration level
8.6.5. Resetting both totalizers
tOtAl REs NO
END
Choose to reset the
two totalizers or not.
Confirm
REs YEs
Fig. 21: Diagram of the "TOTAL" parameter of the Configuration
level
The daily totalizer can be reset from the Process level (see
chap. 8.5).
9. MAINTENANCE AND
TROUBLESHOOTING
9.1. Safety instructions
danger
Risk of injury due to high pressure in the installation.
Stop the circulation of fluid, cut off the pressure and drain the
pipe before loosening the process connections.
Risk of injury due to electrical voltage.
Shut down and isolate the electrical power source before car-
rying out work on the system.
Put the power switch to OFF before carrying out work on the
device.
Observe all applicable accident protection and safety regulati-
ons for electrical equipment.
Risk of injury due to high fluid temperatures.
Use safety gloves to handle the device.
Stop the circulation of fluid and drain the pipe before loosening
the process connections.
Risk of injury due to the nature of the fluid.
Respect the prevailing regulations on accident prevention and
safety relating to the use of aggressive fluids.
23
Maintenance and troubleshooting
Type 8025/8035 battery powered
English