User guide

11
Technical data
6. TECHNICAL DATA
6.1. Conditions of use
Ambient temperature -10 to +60 °C
Air humidity < 85%, non condensated
Height above see level max. 2000 m
Protection class acc. to
EN 60529
IP65, device wired and cable glands tightened and cover lid screwed tight.
6.2. Conformity to standards and directives
The device conforms to the EC directives through the following standards:
EMC: EN 61000-6-2, EN 61000-6-3
LVD: EN 61 010-1
• Vibration: EN 60068-2-6
Shock: EN 60068-2-27
Pressure: article 3§3 of the Pressure Directive 97/23/CE. Acc. to the Pressure Directive 97/23/CE: the device
can only be used in the following cases (depending on the max. pressure, the DN of the pipe and the fluid)
Type of fluid Conditions
Fluid group 1, par. 1.3.a Forbidden
Fluid group 2 par. 1.3.a
DN32
or DN > 32 and PNxDN1000
Fluid group 1 par. 1.3.b PNxDN2000
Fluid group 2 par. 1.3.b
DN200
or PN10
or PNxDN5000
6.3. General technical data
6.3.1. Mechanical data
Part
Material (8045 with flow sensor in
PVDF)
Material (8045 with flow sensor in
stainless steel)
Housing / seal PC / NBR Black PPA / NBR
Cover with lid / seal PC / silicone PSU / silicone
Front foil Polyester
M20x1,5 cable glands / seal PA / neoprene
Screws Stainless steel
Nut PC PPA
Flow sensor (exposed to the fluid) PVDF Stainless steel 316L (DIN 1.4404)
English