Manual

SE 56
38
For each formula you can
associate:
Product quantity
Product name
Maximum time for
batch (safety time for
each formula)
After activating the batch
function from visualization
page, proceed as
illustrated and described in
the aside example.
BATCH FUNCTION CONFUGURATION
VISUALIZATION PAGE WITH BATCH FUNCTION ENABLED
CONFIGURATION of A
BATCH
Configuring formula n°
Product Name
Batch in progress
V
isualizations:
1) batch off: n° batch effected
2) batch on: decrease safety timer
3) configuration: safety timer indefinite if
timer=0 timer disabled
Configuration of batch quantity
Visualization batched product
Input key code
Choose the formula number for associate
quantity batch (between 00 and 15)
Input quantity product for each batch
Enter product name for batch (max 8 characters)
Enter maximum time for batch
If timer = 0, safety timer disabled max time set
= 6000 sec.
Note: If one of the outputs has a batch alarm
assigned. Upon the completion of the batch or
an interruption, an alarm is activated.
From the visualization pages
ENABLE BATCH
Select one of the following functions to enable and configure the batch on the transmitter:
POS. 5.9-5.10: START/STOP batch from input
POS. 6.1-6.2: assign one of the functions ouputs one and/or two
Some examples of operation of such functions are visualized from page 14.
Long push
Long push
Vertical bars behavior
x First bar: volume that is distributing, 100% represents the volume to be delivered, identified by the “drop” symbol
x Second bar: dosing timer, 100% represents the security maximum time set for the batch, “T” symbol
x Third bar: remains deviation measure, as a normal flow measure