User Manual

8644/Rockwell - 33
SYSTEM DESCRIPTION
The intermediate supply is electrically passive.
- logical No process diagram, hence no address required
- mechanical 33 mm add-on dimension
- electrical No current consumption
- fluidic Additional supply
Technical data
Housing dimensions (width x height x depth) 52 mm x 71 mm x 119 mm (incl. snap-on hooks)
Weight 118 g
Permissible temperature (storage/transport) -20 °C to +60 °C
Permissible air humidity 75% mean, 85% occasionally
ATTENTION!
In the range of 0 to +55 °C, suitable precautions must be taken against elevated
humidity (> 85%).
Slight condensation of short duration on the outside of the housing is permissible, e.g.
when the terminal is brought from a vehicle into a closed room.
Permissible air pressure (operation) 80 kPa to 106 kPa (up to 2000 m üNN)
Permissible air pressure (storage/transport) 70 kPa to 106 kPa (up to 3000 m üNN)
Protection type IP 20 to IEC 60529
Protection class Class 3 to VDE 106, IEC 60536
Performance characteristics seen from the overall system