User Manual

8644/Rockwell - 39
SYSTEM DESCRIPTION
The right connection module is electrically passive.
- logical No process diagram, hence no address required
- mechanical 60 mm installation dimension
- electrical No current consumption
- fluidic Right-hand limitation of valve block, right-hand supply
Technical data
Housing dimensions (width x height x depth) 63 mm x 93 mm x 143 mm
Weight 390 g
Permissible temperature (storage/transport) -20 °C to +60 °C
Permissible air humidity 75% mean, 85% occasionally
ATTENTION!
In the range of 0 to +55 °C, suitable precautions must be taken against elevated
humidity (> 85%).
Slight condensation of short duration on the outside of the housing is permissible, e.g.
when the terminal is brought from a vehicle into a closed room.
Permissible air pressure (operation) 80 kPa to 106 kPa (up to 2000 m üNN)
Permissible air pressure (storage/transport) 70 kPa to 106 kPa (up to 3000 m üNN)
Protection type IP 20 to IEC 60529
Protection class Class 3 to VDE 106, IEC 60536
Performance characteristics seen from the overall system