SmartSwitch 9000 9C114 and 9C714 Chassis Installation Guide 9031125-03
Notice Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
Notice Declaration of Conformity Addendum Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: PO Box 5005 Rochester, NH 03867 Mr. J.
Notice iv
Contents Chapter 1 Installing the 9Cx14 Chassis The SmartSwitch 9000 .................................................................................................. 1-1 Features ................................................................................................................... 1-1 Multiple Technology Support ....................................................................... 1-1 Redundant Power Supply Modules.............................................................
Contents vi
Chapter 1 Installing the 9Cx14 Chassis This document contains information necessary to install the SmartSwitch 9000 9C114 and 9C714 chassis. It is designed for the initial installation only.
Installing the 9Cx14 Chassis Redundant Power Supply Modules The 9C114 and 9C714 support the installation of two power supplies for power supply redundancy and load sharing. If a 9C500 Power Box is used, up to six power supplies may be installed. 9C300-1 Environmental Module The 9C300-1 Environmental Module provides out-of-band management capabilities, monitors power supply and environmental status, and has a built-in cooling system.
Installing the 9Cx14 Chassis The descriptions of the seven backplane buses are as follows: System Management Bus 1 The System Management Bus 1, abbreviated SMB-1, is a management bus devoted solely to transferring management information between the modules in the chassis. It is through the SMB-1 that modules inform each other, and the Environmental Module, of their current operating status, diagnostic test results, initialization queries and other information.
Installing the 9Cx14 Chassis The Cell Transfer Matrix (installed in the 9C714 chassis only) The Cell Transfer Matrix provides a Time Division Multiplexed (TDM) based mesh of full duplex, high speed (1.6 Gbps) dedicated interconnections capable of carrying standard ATM cell traffic. These interconnections are a series of point-topoint links between an individual module, and every other module that directly connects to the Cell Transfer Matrix.
Installing the 9Cx14 Chassis Site Guidelines The following guidelines must be followed to select a suitable site for the SmartSwitch 9000. If not, unsatisfactory network performance may result. The site must have an unrestricted free surface area around the SmartSwitch 9000 chassis, allowing for free movement of air. An open space of at least 84 high by 63.5 wide by 81.24 centimeters deep (33 high by 25 wide by 32 inches deep) is the minimum recommended.
Installing the 9Cx14 Chassis Installation Order Once a suitable site has been chosen, the SmartSwitch 9000 may be installed. The unit may be free standing or rack mounted. It is recommended that the SmartSwitch 9000 installation proceed in this order: 1. Mount the chassis to the rack or other secure location. 2. Install the power supply(ies). 3. Attach the Electrostatic Discharge (ESD) Wrist Strap. 4. Install the Environmental Module. 5. Install the Interface Modules. 6.
Installing the 9Cx14 Chassis Rack Mounting the Chassis The chassis can be mounted in a standard 19-inch equipment rack. If the rack is not secured to the floor, it is recommended that the SmartSwitch 9000 be installed in the bottom half of the rack. This will prevent the rack from being top heavy. Two people may be required to lift the chassis into place. The chassis is secured with twelve bolts, six on each side.
Installing the 9Cx14 Chassis Installing a Power Supply At least one power supply must be installed on the rear of the MMAC-Plus chassis. Additional power supplies can be added to achieve redundancy. A power supply is installed by plugging it into either the left or right power supply connector on the SmartSwitch 9000 chassis, as shown in Figure 1-3. Install a power supply by following the steps below: 1.
Installing the 9Cx14 Chassis Slot on Chassis Securing Screw P W R S N B STATUS 100% Load 9C214-1 50% 0% POWER SUPPLY MODULE Tab Securing Screw 100-125v-12A 200-250v-6A 50-60 Hz Figure 1-3.
Installing the 9Cx14 Chassis Attaching the Electrostatic Discharge (ESD) Wrist Strap The ESD Wrist Strap must be attached before handling the Environmental Module or SmartSwitch 9000 Interface Modules. In addition, observe all precautions when handling these modules to prevent damage from ESD. Attach the ESD Wrist Strap by following the steps below: 1. Attach one end of the ESD Wrist Strap to your wrist. 2.
Installing the 9Cx14 Chassis Installing the Environmental Module The Environmental Module is installed in the slot above the module card cage in the front of the SmartSwitch 9000 chassis, as shown in Figure 1-5, by following the steps below: 1. Unpack the Environmental Module by carefully removing it from the shipping box and sliding the two foam end caps off of the unit. (Save the shipping box and packing materials in the event the Environmental Module must be reshipped.) 2.
Installing the 9Cx14 Chassis EPIM STATUS ALARM COM 1 COM 2 9C300-1 ENTER ENVIRONMENTAL MODULE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ALWAYS USE ESD WRIST STRAP WHEN HANDLING MODULES ESD WRIST STRAP GROUNDING RECEPTACLE Figure 1-5. Installing the Environmental Module Installing SmartSwitch 9000 Interface Modules SmartSwitch 9000 Interface Modules can be installed in any of the 14 slots that are available. To install Interface Modules, follow the steps below: 1.
Installing the 9Cx14 Chassis 5. Install the Interface Module in the chassis by sliding it in any available slot and locking down the top and bottom plastic tabs, as shown in Figure 1-6. Take care that the Interface Module slides in straight and properly engages the backplane connectors. When installing the Interface Module, ensure that the circuit card is between the card guides, as shown in Figure 1-6. Check both the upper and lower tracks. 6.
Installing the 9Cx14 Chassis Attaching 9C614 INB Terminator Modules Two 9C614 INB Terminator Modules must be attached to the rear of the SmartSwitch 9000 chassis when Interface Modules that use the INB are inserted in the front of the chassis. These modules provide proper termination for the Internal Network Bus (INB). The INB Terminator Modules are attached by following the steps below: 1. Remove the INB Terminator Modules from the shipping box.
Installing the 9Cx14 Chassis 100% Load 9C214-1 SP S N B NON-SECURED SECURED P W R STATUS 50% 0% NON-SECURED SECURED 9C614 POWER SUPPLY MODULE 100-125v-12A 200-250v-6A 50-60 Hz INB Termination Connectors Figure 1-7. Attaching the INB Terminator Modules Powering up the SmartSwitch 9000 The SmartSwitch 9000 chassis is powered up by following the steps below: 1.
Installing the 9Cx14 Chassis 5. Check that all LEDs on the INB Terminator Module are green. If the LEDs are any color other than green, refer to the INB Terminator Module Installation Guide. 6. Check that the Status and Alarm LEDs on the Environmental Module are green. If the LEDs are not green, refer to the Environmental Module User’s Guide. 7. Check that the System Management Bus (SMB) and the Board OK (BOK) LEDs on the front panel of each installed Interface Module are green.
Installing the 9Cx14 Chassis Weight Unit: Shipping: 19.96 kilograms (44 pounds) 24.95 kilograms (55 pounds) 9C714 MMAC-Plus Chassis Dimensions 76.2 H x 48.3 W x 49.3 D centimeters (30 H x 19 W x 19.4 D inches) Weight Unit: Shipping: 19.96 kilograms (44 pounds) 24.95 kilograms (55 pounds) 9C300-1 Environmental Module Dimensions 12.7 H x 43.2 W x 44.5 D centimeters (5 H x 17 W x 17.5 D inches) Weight Unit: Shipping: 6.5 kilograms (14 pounds) 7.
Installing the 9Cx14 Chassis 9C614 INB Terminator Module Dimensions 21.59 H x 2.22 W x 14.92 D centimeters (8.5 H x 0.875 W x 5.875 D inches) Weight Unit: Shipping: 1-18 0.45 kilograms (1 pound) 0.68 kilograms (1.