Specifications

Command Summary 213
Int
erface Format:dadpinti
Sets the physical interface (i) for data port (dp).
Physical interface can be i (inactive), rs2 (RS232),
rs4 (RS422) or v (V.35). Data port dp must be
offline.
Caution: The selected interface must match
the cable type used on the corresponding port or the
HSP card may be damaged.
Invert_clock Format:dadpinvcm
Controls inversion mode (m) of clock (c) to data port
dp. Clock: t (tx) or r (rx). Inver-sion mode (m): e
(enable) or d (disable). Data port dp must be offline.
Loopback Format:dadplm
Controls loopback operation and direction in data
port dp. Loopback mode (m): d (disable), i(internal)
or e (external). If the data port is in a loopback mode
(internal orexternal), loopback must be disabled
before data port dp can be placed in the other
loopback mode. Data port dp must be online.
Mode Format:dadpmm
Sets data port dp operating mode (m) to frad or fram
(frame relay) to be compatible with the equipment
that is attached to the port.
Offline Format:dadpof
Places the data port dp offline. All DLCIs assigned
to data port dp must be disabled.
Online Format:dadpon
Places data port dp online.
Rate Format:dadprdr
Sets the data rate (dr) of data port dp. Rate:
75-64000-2048000 bps (IBM 9783); 512000 bps.
Data port dp must be offline.
DSUB (da) Commands
DS0 channel (ch): T-1: 1-24; E-1: 1-15 and 17-31. Voice port (vp): all(all), a specific voice port (v1-v8
for analog voice ports; v1a-v8d for digital voice ports) or a range (i,e ., v1a-v2d).
BERT Disable Format:dsbed
Disables the bit error rate (BERT) test running on
the DSUB.