Specifications

© Copyright IBM Corp. 2000 235
Appendix G. Troubleshooting the 9783
This section provides you with the information that can help you solve problems
that may occur when using IBM 9783. Problems are divided into the following
functional areas:
Call accounting channel
Circuit groups
Console port
Frame relay port
Remote unit command channel
Voice port
Translation rules
G.1 Call Accounting Channel
This section presents possible responses to problems associated with the IBM
9783 call accounting channel.
PROBLEM: After changing to FRAD port mode, the accounting channel
does not function.
Cause: The accounting channel is dropped with a mode change.
Response: Disconnect the accounting channel, configure the FRAD port
for ASCII_ASYNC, and reconnect the accounting channel. If
this does not bring the accounting channel up, reboot the
system.
PROBLEM: The accounting channel is not functioning.
Cause: The port is configured for something other than
ASCII_ASYNC.
Response: When entering the mode for an accounting channel (ASCII_
ASYNC), make sure to type at least three letters (ASC...). If
you type only AS, the port will be configured for ASYNC
operation.
G.2 Circuit Groups
This section presents possible responses to problems associated with the IBM
9783 circuit groups.
PROBLEM: Unable to add a processing circuit to a circuit group.
Cause: A circuit group has not been completely deleted.
Response: After a processing circuit is deleted, other circuits in the
circuit group must be deleted before a new processing circuit
can be created.