Specifications

28 IBM Voice Over Frame Relay Perform Guide
3.3.2 Frame Relay Port Configuration
All units in a network must use the same frame format (frame format options
available for the 9783) unless the only connections between them are specified
as non-bundled, data connections
.
Task Command IBM 9783 Status
Place the data port
offline
da dp of
Place data port in frame
relay mode
da dp m fram Data port must be offline
Configure data port clock
mode
da dp clo Data port must be offline
Configure data port
interface
da dp int Data port must be offline
Configure data port block
size
da dp b Data port must be offline
Configure data port LMI
type
fram dp lm ty Data port must be offline
Configure data port LMI
mode
fram dp lm m Data port must be offline
Configure data port
Invert_clock, if required
da dp inv Data port must be offline
Configure data port line
encoding
fram dp li e Data port must be offline
Configure data port line
minimum number of flags
(min_flags)
fram dp li m Data port must be offline
Place data port online da dp on
Create DLCI fram dp d dl cre Data port must be online
Configure DLCI CIR fram dp d dl ci
Configure DLCI EIR fram dp d dl ei
Configure DLCI Tc fram dp d dl tc
Create subDLCIs (cp,
call accounting, call
pro-cessing,voice and
data channels, as
required)
fram dp d dl s sdl cre
Configure DLCI
fragmentation type, if
required
fram dp d dl f t Applies to non-bundled
DLCIs only
Configure DLCI
fragmentation size, if
required
fram dp d dl f s
Enable frame relay traffic
shaping, if required
fram dp d dl tr e