Specifications
32 IBM Voice Over Frame Relay Perform Guide
2. Configure the clock mode for data ports that use BISYNC or HDLC/SDLC. The
choices are:
• INTERNAL
• EXTERNAL
•SPLIT
For example, to select EXTERNAL clock mode for data port A2:
DATA_PORTS A2 CLOCK_MODE EXTERNAL
3. Configure data port rate. Refer to Table 11 on page 29 for a list of the available
data rates. The following example configures data port A2 for a data rate of
64000 bps.
DATA_PORTS A2 RATE 64000
4. Configure the FRAD port type. The choices are:
• ASCII ASYNC (for call accounting)
• ASYNC
•BISYNC
• HDLC / SDLC
For example, to configure FRAD A2 for ASYNC opera-tion, issue the following
command:
FRAD A2 MODE ASYNC
5. Configure the interface type:
DATA_PORTS A2 INTERFACE RS232 (or V35, RS422, or INACTIVE)
6. Configure the ASYNC parameters. The choices are:
• CHARACTER_BITS
•STOP_BITS
• PARITY_ERROR_SUBSTITUTE
• SUB_CHARACTER
• BUILD_TIMEOUT
For example, to select 8 character bits for FRAD A2, issue the following
command line:
FRAD A2 ASYNC_CONFIG CHARACTER_BITS 8_BITS
7. Configure the BISYNC parameters. The choices are:
• EBCDIC
•8ASCII
•7ASCII
• MIN_SYNC_PAIR
• IDLE_LINE_FILL
• SYNC_CHAR_CODE
• PAD_CHAR_CODE
For example, to select
EBCDIC for FRAD A2, issue the following command:
FRAD A2 BISYNC_CONFIG EBCDIC
8. Configure the HDLC parameters. The choices are:
• CRC_SIZE
• LINE_ENCODING
• MIN_FLAGS
• IDLE_LINE_FILL