Specifications

80 IBM Voice Over Frame Relay Perform Guide
4.2.1.7 Modifying Dial Tones and Times
The IBM 2212 voice card default setting is American standard dial tones and
timers. This sample voice configuration shows you how to modify dial tones and
times for each country.
Table 26. Dial Tone and Timer Japan
1. To modify dial tone and ring-back tone:
2212-A *TALK 5
CGW Operator Console
2212-A +EVENT
Event Logging System user console
2212-A ELS>DISPLAY SUBSYSTEM voic all
2212-A ELS>EXIT
2212-A +
2212-A *TALK 2
00:00:37 VOIC.001: Call Setup recv nt 4 int Voice/0, trans nt 5 int Voice/1
DLCI 0 sub 0 cir 0 NID 0.0.0.0 Dest 102
00:00:37 VOIC.001: Call Connect recv nt 5 int Voice/1, trans nt 4 int Voice/0
DLCI 0 sub 0 cir 0 NID 0.0.0.0
00:00:39 VOIC.001: Call Answer recv nt 5 int Voice/1, trans nt 4 int Voice/0
DLCI 0 sub 0 cir 0 NID 0.0.0.0
00:00:43 VOIC.001: Call Release recv nt 4 int Voice/0, trans nt 5 int Voice/1
DLCI 0 sub 0 cir 0 NID 0.0.0.0 Cause 0
00:00:47 VOIC.003: Call Release recv nt 4 int Voice/0, disc unroutable
DLCI 0 sub 0 cir 0 NID 0.0.0.0 Cause 0
On 1
(msec)
Off 1
(msec)
On 2
(msec)
Off 2
(msec)
Freq 1
(Hz)
Freq 2
(Hz)
Level 1
(dB)
Level 2
(dB)
Dial Tone 0 0 0 0 400 400 -16 -16
Ring Back 1000 2000 1000 2000 400 400 -22 -22
Busy Tone 500 500 500 500 400 400 -20 -20
Fast Busy 500 500 500 500 400 400 -16 -16
Warble 100 100 100 100 1400 2060 -16 -16
DTMF 100 100 -7
2212B Voice Config>
SET TONE DIAL
On1(0to32767ms)[0]?
Off1 (0 to 32767 ms) [0]?
On2(0to32767ms)[0]?
Off2 (0 to 32767 ms) [0]?
Freq1 (300 to 3000 Hz) [350]?
400
Freq2 (300 to 3000 Hz) [440]?
400
Level1 (-7 to -22 dB) [-16]?
Level2 (-7 to -22 dB) [-16]?
2212A Voice Config>
SET TONE RING-BACK
On1 (0 to 32767 ms) [2000]?
1000
Off1 (0 to 32767 ms) [4000]?
2000
On2 (0 to 32767 ms) [2000]?
1000
Off2 (0 to 32767 ms) [4000]?
2000
Freq1 (300 to 3000 Hz) [440]?
400
Freq2 (300 to 3000 Hz) [480]?
400
Level1 (-7 to -22 dB) [-22]?
Level2 (-7 to -22 dB) [-22]?