Use and Care Manual

18 49-2000706 Rev. 0
INSTALLATION INSTRUCTIONS
Installation Instructions
1
INSTALL HOOD SUPPORT
IMPORTANT: Framing must be capable of
supporting 100 lbs.
Locate a minimum of 2 vertical studs for the
installation bar by tapping drywall with a hammer
or use a stud finder.
Level the installation bar and center left to right
above the marked line. Hold bar against the wall.
Drill 1/8” pilot holes at the 2 vertical stud locations
through holes in the installation bracket. Secure
the installation bar with supplied screws (A) as
shown above.
Drill Bottom Mounting Hole Locations:
Hang hood on installation bar or use the table
below to mark screw holes locations. NOTE: If
installing to soffit or cabinet, push hood flush to
the soffit or cabinet before marking screw hole
locations.
Remove the hood and drill 5/16” clearance holes at
marked locations “A” and “B”.
1
INSTALL HOOD SUPPORT (cont.)
Install wall anchors (C) by tapping the anchors with
a hammer to seat the teeth of the flanges into the
wall. This keeps anchor from rotating.
Drive the anchor screws until the barrels crimp
against the inside of the wall.
Remove the screws from the wall anchors before
installing the hood.
2
INSTALL DAMPER
IMPORTANT: Remove shipping tape from damper
and check that damper moves freely.
Install Top Damper:
The motor mounting plate comes pre-installed in
the hood for top venting.
Install the top damper to the hood body as shown
in Figure A using screws (B) from top of hood.
Install Back Damper:
In case of back venting through the wall, back
damper accessory UXBDA812 must be purchased
separately.
Uninstall the motor mounting plate from top venting
position. Save the screws.
Remove the square knockout panel on hood body
for back venting.
Remove the two screw knockout holes on the
motor mounting plate as shown in Figure C.
Install the motor mounting
plate to back panel so that
the arrow on plate is pointing
upwards and on the right
side.
Push plate in until metal
clips engage. Fasten plate
through screw knockouts
shown in Figure C using the
two screws saved.
Install the back damper to the hood body as shown in
Figure B using screws provided with the accessory.
Install the metal plate provided with the accessory
to cover the opening for top damper.
Installation Bar
Centerline of
Installation Space
16-3/4”
24” minimum over electric range
or cooktop, or 30” minimum over
gas range or cooktop, and 36”
recommended maximum.
Figure A
Figure B
B
A
Bottom of Hood
Centerline of
Installation Space
“A” “B”
30” Model 8-3/4”
5”
36” Model 13-3/4”
TOP
Figure C (Panel will look
different for single motor)
Screw Knockouts