3.9. System
This selection contains functions which are more applicable to system operation than to picture
adjustment.
3.9.1. User
Settings: USER 1, 2, 3, 4
A predefined setting stored under a user name can be selected. Several settings of the HQView-2xx
can be stored under a user name. Thus, different users can store their preferred HQView-2xx settings
and recall these profiles by picking up their user name from this menu.
Note: Using the Web interface, (any number of) settings can also be stored/restored to/from a PC disc
drive. This feature is only available on V2 hardware
3.9.2. Names/Profiles
The Names/Profiles menu provides input masks to rename the generic input channels and user names.
User names and input channel names can be changed to any word with a maximum of 12 alpha
numeric characters with a value range of 0-9, A-Z and blank.
The Names/Profiles menu allows the user to store profiles under a certain user name. It also allows to
copy user profiles by loading a profile stored under one user name and save it under another user
name. Reset Profile allows to restore default HQView-4xx settings for the currently selected user.
3.9.3. Test Pattern
Settings: Grey V Bars, Grey H Bars, Aspect Test, Multi Test, Warp Adjust, SMPTE, PLUGE
List box to choose a test pattern. When the OSD menu is off the test pattern can be toggled through by
pressing the up and down keys of the keypad.
3.9.4. Display Mode
The “Display Mode” can be set to either Low Latency or Best Picture. In Best Picture optimum image
processing is applied, whereas in Low Latency mode the lowest latency is achieved. The flicker of
interlaced video is not suppressed totally for the latter setting. Thus it has the disadvantage of
conventional CRT TVs, but also their advantage of almost no delay in response, which is important for
applications such as gaming, simulation or imaging in medical treatment.
3.9.5. Switching Transition
When switching input channels (here 3GSDI and Test Pattern only) by default the last frame of the prior
displayed image is frozen and displayed until a stable image of the new input channel can be shown.
The switchover process is supposed to be as seamless as possible. The source and monitor add
switching noise due to unforeseeable activity of the firmware in said devices. By default HQView is in
auto frame rate switching and I/O lock mode. In order to get a best smooth switching result with the
source and monitor I/O lock and auto frame rate switching have to be switched off in the Output/Display
Type menu.