ULTRA QUIET & OIL FREE AIR COMPRESSOR OwnER'S MAnUAL CALIFORnIA AIR TOOLS 10020DCAD WWW.CALIFORNIAAIRTOOLS.
AIR COMPRESSOR TAbLe OF CONTeNTS INTROduCTION IntroductIon __________________________________2 Important Safety InStructIonS _______________5 aIr compreSSor componentS__________________6 pre-operatIon checklISt ______________________7 package contents & assembly____________________7 Inspect for damage _____________________________7 Save packaging ________________________________7 compressor location ___________________________7 electrical power ________________________________8 operatIng the aIr compreSS
AIR COMPRESSOR how to find a local service center: even quality built equipment might need service or repair parts. Contact the California Air Tools Customer Service department: Phone: 1-866-409-4581 Online: WWW.CALIFORNIAAIRTOOLS.COM please provide the information below: Model number and Serial number and specifications shown on the Model number/Serial number plate. Part number or numbers shown in the parts list section of the owner’s manual for your air compressor model.
AIR COMPRESSOR WARNING WARNING FLYING OBJECTS RISK TO BREATHING Dust or dust-like particulates caused by power-sanding, sawing, grinding, drilling or any other construction-like activities can contain contaminants that are harmful to breathe. Always use your air compressor in a well-ventilated and clean area. Never breathe the air that comes directly out of the air compressor or air hose. This air is not suitable for breathing. Always wear approved safety equipment.
AIR COMPRESSOR WARNING WARNING EXPLOSION EXPLOSION Improper care could lead to the air tank bursting or exploding. Drain air tank daily or after each use to prevent moisture buildup in the air tank. Rust can weaken the air tank and cause leaks or bursting. If rust is detected, replace tank immediately. Do not try to repair the air tank by welding, drilling or modifying it in any other way. These modifications can weaken the air tank and cause a hazardous condition.
AIR COMPRESSOR 6 Customer Support: 1-866-409-4581
AIR COMPRESSOR pre-operatIon checklISt Inspect for damage package contents before using the air compressor, make sure the air tank is not damaged, inspect all parts for damage, and check that all pipes are firmly connected. model: 10020dcad do not use the air compressor if any damage is found. If damaged, have an authorized service center inspect and test the air compressor to ensure that is working properly.
AIR COMPRESSOR electrical power electrical extension cord electrical power requirements Inspect all electrical extension cords to ensure that they are free of Inspect all electrical extension cords to ensure that they are free of damage. When using an extension cord, use a heavy-duty cord that is no more than 25 feet long and at least 14 gauge. use only a 3-wire extension cord that has a 3-blade grounding plug. OPeRATINg The AIR COMPReSSOR Save this manual for future reference.
AIR COMPRESSOR test run WARNING before using the air compressor for the first time, complete a test run as follows: 1. Turn the power switch to the OFF position. Plug the power supply cord into a power supply socket. Start the air compressor by turning the power switch to the ON position. The pressure gauge reading will slowly rise as pressure increases inside the air tank. When the gauge reading reaches 115 -120 PSI, the pressure switch will automatically turn the power off.
AIR COMPRESSOR MAINTeNANCe air drying column - desiccant draining the air tank The frequency at which you should drain the air tank and air dryer depends on the environmental conditions and the amount of operating time logged. daily draining is recommended to not damage the air compressor motor, dryer, tank and components. After 4000 hours of use the Activated Alumina desiccant needs to be replaced. unscrew the air drying column bottom cap. Remove the old desiccant (disguard) and add new desiccant. 1.
AIR COMPRESSOR TROubLeShOOTINg proBlem poSSIBle cauSe poSSIBle SolutIonS Air leaks at connections. Let the compressor build pressure in the tank, to the maximum pressure if possible. brush soapy water on air connections and look carefully for air bubbles. Tighten leaky connections. If the problem persists, contact the seller for further advice. Non-return valve seal is defective. Let the air in the tank flow out until all the pressure is released.
AIR COMPRESSOR SPeCIFICATIONS electrical circuit Pressure switch Electric cord for motor Overload protector (MAX temperature 135°C) Motor Red cords for Capacitor Solenoid valve Electric cord for motor Earth wire (Green) air passage drawing Air intake Pressure switch Drain valve Safety valve Pressure gauge Regulator Compressor Tank Check valve Solenoid valve 12 Pressure gauge Filter Ball valve Customer Support: 1-866-409-4581
AIR COMPRESSOR CALIFORNIA AIR TOOLS INC. LIMITed WARRANTy This warranty is limited to Air Compressors distributed by: California Air Tools, Inc. 8560 Sieper Viva Road, unit 3 San diego, CA 92154 limited Warranty California Air Tools Inc. will repair or replace, free of charge, to the original retail customer who purchased a California Air Tools, Inc. Air Compressor from an authorized dealer, distributor or distributor’s dealer in North America. This warranty does not transfer to subsequent owners.
AIR COMPRESSOR exclusions In addition to the foregoing disclaimers, limitations and terms, this limited warranty shall not apply to and does not cover accessories, nor does it cover products that are in any way subject to any of the following: 1. Improper setup, installation or storage. 2. Lack of proper maintenance and service. 3. Accident, damage, abuse or misuse. 4. Abnormal operating conditions or applications. 5.
AIR COMPRESSOR PROduCT RegISTRATION To register your product, please complete the information below and mail to the mailing address at the end of this page. 1.