Owner's Manual

13
Customer Support: 1-866-409-4581
AIR COMPRESSOR
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTIONS
Pressure drop in the tank. Air leaks at connections.
Let the compressor build pressure in the tank, to
the maximum pressure. Brush soapy water on air
connections and look carefully for air bubbles.
Tighten leaky connections.
Pressure drop in the tank Check Valve Spring Compressed
Release the air in the air tank until all of the
pressure is released. Then remove the check valve
cap and spring. Clean and elongate (stretch) the
check valve spring. Reinstall the parts.
The compressor stopped and
does not start.
The thermal protector turned on because
the motor is overheating.
Check that the main voltage corresponds to the air
compressor specifications. An extension cord that
is too thin or too long can cause a voltage drop and
cause the motor to overheat.
Excessive use (over 1 hour continuous use) can
cause the motor to overheat
Allow the motor to cool down.
Motor windings are burned out. Contact Customer Support.
The motor does not start and
makes a humming noise.
Low voltage supply to the motor See below
The motor does not start or starts
slowly.
Low voltage supply to the motor.
Check that the main voltage corresponds to the air
compressor specifications.
An extension cord that is too thin or too long can
cause a voltage drop.. Use heavy duty extension
cords.
Ensure that the air compressor is plugged into a
fully functional power outlet
The compressor is noisy with
metallic clangs.
Compressor head gasket or reed valve is
damaged
Stop the compressor and contact the parts dealer.
The compressor does not reach
the maximum pressure.
Compressor head gasket or reed valve is
faulty.
Stop the compressor and contact the parts dealer.
The compressor doesn't seem to
provide as much air as it did
when new and/or the compressor
cuts off within a much shorter
time period.
The pressure switch needs adjusting. Contact Customer Support
The tank is full of water due to
condensation.
Open the drain valve and release the water from
the tank.
The motor pump unit does not
stop when the tank pressure
reaches its maximum working
pressure (130 PSI).
Pressure switch defective or needs
adjusting.
Stop the compressor immediately and contact
Customer Support.