Note:
1. The air compressor should only be placed in a well-ventilated and clean area.
2. Keep the air compressor on a firm and flat surface, with adequate space surrounding it for
ventilation.
3. If the air compressor needs repair or becomes damaged, turn off the power and drain the
tank.
4. Motors cannot be more than 10% lower or higher than the standard voltage.
5. When the compressor is running, do not touch its hot surfaces.
Routine maintenance
1. Always listen for unusual sounds, vibrations or high-pitched noises.
2. Open the drain valves to empty the air tank at least once per day.
Weekly maintenance
1. Clean the air filter weekly. Replace it with a new one after 500 hours of use.
2. Open the safety valve to ensure that it is operational.
3. Ensure that the pressure switch and check valve are operating normally.
4. Inspect all screws and connections, and tighten if any are loose.
Quarterly maintenance
1. Inspect all screws and connections, and tighten if any are loose.
2. Clean the compressor's exterior, and check for leaky connections.
3. Check the valve plate, valve, piston rings, etc., to ensure that they are operating normally.