ULTRA QUIET & OIL FREE AIR COMPRESSOR Ow n ER'S MAn UAL CALIFORn IA AIR TOOLS 10020DC WWW.CALIFORNIAAIRTOOLS.
AIR COMPRESSOR TAb Le OF CONTe NTS INTROd u CTION In t r o d u c t Io n __________________________________2 Impo r t a n t Sa f e t y In St r u c t Io n S _______________5 a Ir c o mpr e SSo r c o mpo n e n t S__________________6 pr e -o pe r at Io n c h e c k l ISt ______________________7 package c ontents & a ssembly____________________7 Inspect for d amage _____________________________7 Save packaging ________________________________7 c ompressor l ocation ___________________________7 e lectrical powe
AIR COMPRESSOR h ow to find a local service center: even quality built equipment might need service or repair parts. Contact the California Air Tools Customer Service d epartment: Phone: 1-866-409-4581 Online: WWW.CALIFORNIAAIRTOOLS.COM please provide the information below: Model number and Serial number and specifications shown on the Model number/Serial number plate. Part number or numbers shown in the parts list section of the owner’s manual for your air compressor model.
AIR COMPRESSOR WARNING WARNING FLYING OBJECTS RISK TO BREATHING Dust or dust-like particulates caused by power-sanding, sawing, grinding, drilling or any other construction-like activities can contain contaminants that are harmful to breathe. Always use your air compressor in a well-ventilated and clean area. Flying objects can cause injury to the eyes, head and other parts of the body.
AIR COMPRESSOR WARNING WARNING EXPLOSION EXPLOSION Improper care could lead to the air tank bursting or exploding. Drain air tank daily or after each use to prevent moisture buildup in the air tank. Rust can weaken the air tank and cause leaks or bursting. If rust is detected, replace tank immediately. Do not try to repair the air tank by welding, drilling or modifying it in any other way. These modifications can weaken the air tank and cause a hazardous condition.
AIR COMPRESSOR 6 Customer Support: 1-866-409-4581
AIR COMPRESSOR pr e -o pe r at Io n c h e c k l ISt Inspect for d amage package c ontents before using the air compressor, make sure the air tank is not damaged, inspect all parts for damage, and check that all pipes are firmly connected. model: 10020d c d o not use the air compressor if any damage is found. If damaged, have an authorized service center inspect and test the air compressor to ensure that is working properly.
AIR COMPRESSOR e lectrical power e lectrical e xtension c ord e lectrical power r equirements Inspect all electrical extension cords to ensure that they are free of Inspect all electrical extension cords to ensure that they are free of damage. When using an extension cord, use a heavy-duty cord that is no more than 25 feet long and at least 14 gauge. u se only a 3-wire extension cord that has a 3-blade grounding plug. OPe RATINg Th e AIR COMPRe SSOR Save this manual for future reference.
AIR COMPRESSOR t est r un WARNING before using the air compressor for the first time, complete a test run as follows: 1. Turn the power switch to the OFF position. Plug the power supply cord into a power supply socket. Start the air compressor by turning the power switch to the ON position. The pressure gauge reading will slowly rise as pressure increases inside the air tank. When the gauge reading reaches 115 -120 PSI, the pressure switch will automatically turn the power off.
AIR COMPRESSOR MAINTe NANCe a ir d rying c olumn - d esiccant d raining the a ir t ank The frequency at which you should drain the air tank and air dryer depends on the environmental conditions and the amount of operating time logged. d aily draining is recommended to not damage the air compressor motor, dryer, tank and components. 1. Place the air compressor above a container capable of holding water. A pan with a dry towel would be advised. Locate the drain valve at the bottom of the air tank.
AIR COMPRESSOR TROu b Le Sh OOTINg pr o Bl e m po SSIBl e c a u Se po SSIBl e So l u t Io n S Air leaks at connections. Let the compressor build pressure in the tank, to the maximum pressure if possible. brush soapy water on air connections and look carefully for air bubbles. Tighten leaky connections. If the problem persists, contact the seller for further advice. Non-return valve seal is defective. Let the air in the tank flow out until all the pressure is released.
AIR COMPRESSOR SPe CIFICATIONS e lectrical c ircuit Pressure switch Electric cord for motor Overload protector (MAX temperature 135°C) Motor Red cords for Capacitor Solenoid valve Electric cord for motor Earth wire (Green) a ir passage d rawing Air intake Pressure switch Drain valve Safety valve Pressure gauge Regulator Compressor Tank Check valve Solenoid valve 12 Pressure gauge Filter Ball valve Customer Support: 1-866-409-4581
AIR COMPRESSOR CALIFORNIA AIR TOOLS INC. LIMITe d WARRANTy This warranty is limited to Air Compressors distributed by: California Air Tools, Inc. 8560 Sieper Viva Road, u nit 3 San d iego, CA 92154 l imited Warranty California Air Tools Inc. will repair or replace, free of charge, to the original retail customer who purchased a California Air Tools, Inc. Air Compressor from an authorized dealer, distributor or distributor’s dealer in North America. This warranty does not transfer to subsequent owners.
AIR COMPRESSOR e xclusions In addition to the foregoing disclaimers, limitations and terms, this limited warranty shall not apply to and does not cover accessories, nor does it cover products that are in any way subject to any of the following: 1. Improper setup, installation or storage. 2. Lack of proper maintenance and service. 3. Accident, damage, abuse or misuse. 4. Abnormal operating conditions or applications. 5.
AIR COMPRESSOR PROd u CT Re g ISTRATION To register your product, please complete the information below and mail to the mailing address at the end of this page. 1.