Protection requirements for a mast or tower installation
If the AP or SM is to be mounted on a metal tower or mast, then in addition to the general protection
requirements (above), the following requirements must be observed:
The equipment must be lower than the top of the tower or its lightning air terminal.
The metal tower or mast must be correctly grounded.
A grounding kit must be installed at the first point of contact between the drop cable and the tower, near
the top.
A grounding kit must be installed at the bottom of the tower, near the vertical to horizontal transition
point. This grounding kit must be bonded to the tower or tower ground bus bar (TGB), if installed.
Schematic examples of mast or tower installations are shown in Figure 24.
Figure 24 Grounding and lightning protection on mast or tower