User Guide

Table Of Contents
PMP 450 Planning Guide
5 MHz Channel 133 130 125 117 107
Table 13 Link Budget Details Dynamic Rate Adapt, 3.5GHz
Product Parameter
Performance Details
1x
2x
4x
6x
8x
PMP 450
§§
Modulation QPSK-SISO QPSK-MIMO 16-QAM-MIMO 64-QAM-MIMO 256-QAM-MIMO
3.5GHz Max.
LOS Link Budget
(no fade margin)
20 MHz channel
bandwidth
with Integrated
SM antenna
11.9 mi / 19.04
km
11.9 mi / 19.04
km
6.1 mi / 9.76 km 2.7 mi / 4.32 km 1.2 mi / 1.92 km
with Reflector
Dish that adds 11
dB to SM Range
40 mi / 64 km 40 mi / 64 km 21.5 mi / 34.4 km 9.6 mi / 15.36 km 4.3 mi / 6.88 km
3.5GHz Max.
LOS Link Budget
(no fade margin)
10 MHz channel
bandwidth
with Integrated
SM antenna
17.2 mi / 27.52
km
17.2 mi / 27.52
km
6.9 mi / 11.04 km 3.5 mi / 5.6 km 1.7 mi / 2.72 km
with Reflector
Dish that adds 11
dB to SM Range
40 mi / 64 km 40 mi / 64 km
24.6 mi / 39.36
km
12.5 mi / 20 km 6.2 mi / 9.92 km
3.5GHz Max.
LOS Link Budget
(no fade margin)
5 MHz channel
bandwidth
with Integrated
SM antenna
20.9 mi / 33.44
km
20.9 mi / 33.44
km
10.7 mi / 17.12
km
4.8 mi / 7.68 km 1.9 mi / 3.04 km
with Reflector
Dish that adds 11
dB to SM Range
40 mi / 64 km 40 mi / 64 km 38 mi / 60.8 km 17 mi / 27.2 km 6.6 mi / 10.56 km
3.5GHz Max.
Aggregate
Throughput with
1/16 Cyclic Prefix
to 1 SM
(75%/25%
DL/UL Ratio)
RF Link Test
20 MHz Channel:
(up+down)
13 Mbps 30 Mbps 59 Mbps 96 Mbps 129 Mbps
10 MHz Channel:
(up+down)
6 Mbps 13 Mbps 26 Mbps 42 Mbps 55 Mbps
5 MHz Channel:
(up+down)
2 Mbps 4 Mbps 9 Mbps 14 Mbps 18 Mbps
3.5GHz Nominal
Per-Chain
Receive SM RX
Sensitivity
(including
FEC)
***
20 MHz Channel -87 dBm -87 dBm -80 dBm -73 dBm -66 dBm
10 MHz Channel -90 dBm -90 dBm -83 dBm -77 dBm -70 dBm
5 MHz Channel -92 dBm -92 dBm -86 dBm -80 dBm -73 dBm
Link Budget,
Integrated (dB)
20 MHz Channel 129.2 129.2 123.3 116.3 109.3
10 MHz Channel 132.4 132.4 124.5 118.6 112.5
§§
Maximum setting of Max Range parameter is 40 mi.
***
PMP 450 devices include a dual polar antenna; Channel A (-45 deg.) and Channel B (+45 deg.). Listed receive
sensitivity corresponds to single-channel readings.
1-44