PMP 450 Planning Guide
Deployment scenario 2Replacing PMP 430 equipment (10 MHz
Channel Bandwidth)
Deployment scenario 2 assumes that the existing network is comprised of PMP 430 equipment with the
configuration listed below in Table 24. The migration in this scenario results in a complete replacement of
PMP 430 series equipment with PMP 450 equipment.
Table 24 Deployment scenario 2
Term Definition
Existing System Release
12.2.2
Existing Number of Sectors
6
Existing Modulation
OFDM
Existing Frequency Re-use Pattern
ABC ABC
Existing Ch BW (MHz)
10
Existing Aggregate Tower Throughput (Mbps)
135
Existing Total Bandwidth Used (MHz)
30
Existing Additional Frequencies Available (MHz)
0
Replace Legacy Subscribers with 450 SMs
Optional (PMP 430 Interop enables
PMP 430 SMs to register to PMP
450 AP)
Resulting Number of Sectors
6
Resulting Modulation
OFDM (MIMO)
Resulting Frequency Re-use Pattern
ABC ABC
Resulting Ch BW (MHz)
10
Resulting Total Bandwidth Used (MHz)
30
Resulting Aggregate Tower Throughput (Mbps)
234
Resulting Percentage Increase in Aggregate Tower Throughput
173%
pmp-0047 (March 2014)
1-65