Instructions / Assembly

9
ASSEMBLY INSTRUCTIONS
7
7. Screw gas hose and regulator to propane cylinder
(not included). Do not cross-thread.
Place the propane cylinder into the cylinder housing (F),
then close the door.
WARNING: Use a standard 20 lb. propane cylinder
only.
Use this heater only with a propane vapor withdrawal
supply system. See chapter 5 of the standard for
storage and handling of liquefied petroleum gas,
ANS/NFPA 58. Your local library or fire department
should have this book.
A minimum supply pressure of 8 W.C. is required for
the purpose of input adjustment for propane gas.
Storage of an appliance indoors is permissible only if
the cylinder is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a
well-ventilated area out of the reach of children. A
disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage
or any other enclosed area. The minimum permissible
gas supply pressure of 8 W.C. is required for purpose
of input adjustment. A minimum of 17,000 BTUs per
hour is the required input rating for a heater with a
rating less than full.
The pressure regulator and hose assembly supplied
with the appliance must be used.
The installation must conform with local codes, or in the
absence of local codes,with national fuel gas code,
ANS Z223.1/NFPA54, natural gas and propane
Installation Code, CSA B149.1, or propane storage and
handling code, B149.2.