Instructions / Assembly

IMPORTANT SAFETY INFORMATION ABOUT
PROPANE (LP) GAS
A self cont ained LP-gas cylinder for use w ith this appliance must have a
capacity of 20 lbs/9 kgs. and must be equipped with a Type 1 connector and an
OPD (overfill protection device). See Figure 1.
The LP-gas supply c ylinder to be used m ust be constructed and marked in
accordance with the specification for LP-gas cylinders of the U.S. Department
of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinder, Sphere and Tubes for the Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and
shall not be used in a building, garage or any other enclosed space.
When this appliance is not is use, the gas must be turned off at the supply
cylinder.
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the
reach of children .Disconnected cylinders must have threaded valve plugs
tightly installed and must not be stored in a building, garage or any other
enclosed areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA
2.41-2012 “ Outdoor Decorative Gas Appliances”
The gas hose is routed through a “U” bolt to prevent the hose from coming in
contact with the burner. DO NOT remove the hose from the “U” bolt.
See Figure 2.
Figure 1 Figure 2
SPECIFICATIONS
INPUT 40,000 Btu/hr 30,000 Btu/hr Low fire
Propane Regulator
Pressure
11 in / 2.74 kPa water
column
Natural Gas Minimum
Inlet Pressure
7 in / 1.74 kPa water
column
Clearances to
combustible surfaces
Sides: 24in./60.96cm Top: 72 in. / 182.88 cm