Service manual

Foil Place and Table Detent Airflow Sensors
The foil place sensor detects airflow when there is a vacuum created and holding a foil.
If air is flowing then it indicates a foil was not picked up (maybe the stack was empty) or
a foil fell off before the vacuum was shut off (maybe the vacuum was too weak).
Regardless, if there is supposed to be a vacuum and there is airflow it will create a fault.
Determine the cause and reset the fault on the HMI prior to cycling the machine again.
The Table Detent sensor measures airflow coming up through the support of the dial
plate. There is constant air pressure on the table. If the table comes out of detent, then
air flows and this triggers a fault that immediately shuts the machine off. This is to
prevent the machine from jamming and an additional safety feature. If the table comes
out of detent rotate it back into detent. There is only one position that the table can be in
and you should be able to feel it go back into detent. You may need to wiggle it into
position. Once this is done, reset the fault on the HMI before cycling the machine again.
Table Detent Airflow Sensor
(The larger of the two)
Foil Place
Airflow Sensor
(The smaller of
the two
14