Service manual

Base Unit 000-000-B000
Drive Sub Assembly
The Camco Drive unit and Baldor Motor are the central drive units of the
machine.
The center shaft protruding up-wards from the motor is fitted with a air seal.
Should the dial be broken loose from its home position, the detents, P7,
disengage, and the air pressure switch (not-shown) senses the loss of pressure.
This pressure switch (not-shown) can only be reset in the home position. Again,
this is a single position on the dial. Rotate the dial until the home position is
achieved and the air sensor will de-activate. Press the Green Start button on
the Control Panel to re-start machine.
A
lso, Item 3, houses the sensor for the release of the foil from the sucker cup on
the foil place station.
Item P5, shows the sensor for the home position of the machine.
20