Service manual

Main Controls:
Powering Up:
Ensure lower guards and perimeter guards are in place. Plug power into the machine and
connect the air pressure. Turn the power switch to the “ON” position. The touch screen
should come on and will indicate "Power
Off." Now press the green "E-Stop
Reset" button on the panel above the
"Emergency Stop."
Indicator should now read “Powering
Up” and “E-Stop Reset” button should
now be lit up green.
Next, verify that the machine is in Auto
or Manual Mode.
Manual vs. Auto Mode:
Select “Manual” or “Auto” on the touch screen.
When in “Manual” mode, press and hold “Cycle Start”
to cycle the table. When you release “Cycle Start” the
table will stop. This is useful for slowly positioning and
timing the machine, or for troubleshooting a particular
process during a cycle.
When in “Auto” mode, press “Cycle Start” once to start
cycling the table and “Cycle Stop” to stop cycling the
table. When you press “Cycle Stop” the machine will
continue briefly until the heater head rises off of the
table. This is to prevent the heater head staying down
on a container and seal.
Cycle Speed:
Set the Machine Cycle Speed with the dial. Actual speed is
indicated on the touch screen.
Note: This number will not change
unless the machine is in motion either
“Manual” or “Auto.” This indicator is
a measured cycle rate and the machine must be running to
measure the rate.
6