Manual

CENTRE STOP
90° 90°
5.9 - Re-Handing the Frog Motors
RIGHT
LEFT
ON RECEIPT YOUR FROG MOTORS WILL HAVE BEEN SETUP FOR YOU AS A
PAIR I.E LEFT HAND AND RIGHT HAND BUT SHOULD YOU NEED TO RE-HAND
THESE MOTORS THE FOLLOWING INSTRUCTIONS WILL SHOW YOU HOW.
SCREW THE M10 X 100MM BOLT (A) AND THE M10 NUT (B) INTO THE
MOTOR TRANSMISSION ARM AS SHOWN IN FIGURE ABOVE. FOR R/H
MOTOR INSTALLATION AND FOR L/H MOTOR INSTALLATION SEE FIGURE
ABOVE.
ENSURE THAT THE MOTOR IS CORRECTLY FASTENED INTO THE CASING
WITH THE NUTS AND WASHERS PROVIDED. INSERT THE LIMIT ARM (C)
BETWEEN THE MOTOR TRANSMISSION ARM AND THE FROG SHOE. GIVE THE
GATE A COMMAND TO OPEN, WHEN THE GATE COMES TO THE OPEN POSI-
TION AND THEN ADJUST THE SCREW (A).
CLOSE THE GATES SO THAT SCREW (A) MEETS THE LINK ARM. THEN OPEN
THE GATE AND ADJUST (A) ACCORDINGLY. DURING ADJUSTMENT ALLOW THE
GATE TO PUT ADEQUATE PRESSURE ONTO THE CENTRE STOP BUT
ALLOWING THE GATE TO BE RE-LOCKED ONTO THE SHOE AFTER MANUALLY
RELEASING THE GATE.
WHEN ADJUSTMENT IS FINISHED FASTEN NUT (B).
28