AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2081 - G2081I
“IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS” 1 Legend This symbol indicates sections concernig safety This symbol indicates notes to communicate to users. 2 Destination and limits of use 2.
GEARMOTOR Power supply: 230V A.C. 50/60Hz Motor power supply: 230V A.C. 50/60Hz Max. absorption: 2.8A Condenser: 35µF Rated power: 330W Max. torque: 250Nm Reduction ratio: 1/202 Opening time: 4÷8 s Operative intermittence: 30 % Protection level: IP54 Weight: 90 kg Insulation class: I 4.
.4 Size measurements Measurements in mm ENGLISH 5 Installation Installation must be carried out by expert qualified personnel and in full observance of regulations in force. 5.
.3 Cable list and minimun thickness Connections Type of cable 3G x 1,5 mm2 3G x 2,5 mm2 3G x 4 mm2 230V motor power supply 3 x 1 mm2 3 x 1,5 mm2 3 x 2,5 mm2 2 x 0,5 mm2 2 x 0.
5.4 Fitting for unit base - Prepare a hole to house the fixing base and prepare sheath tubes from the branch pit for the connections. - Assemble the four anchoring clamps at the base. - Fill the hole with concrete and immerge the clamps and the fixing base, paying particular attention to the sheath tube which must go through the hole at the base. The base must be perfectly level, clean and with the screw threads fully on the surface. Wait until everything is solidified – at least 24 hours.
5.5 Installation of the Unit ENGLISH The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici S.p.A. - Open the door with the proper key, remove the top dome and take out the inspection door. - The barrier is designed to be installed on the left of the gateway as seen from inside. SX Lever arm DX - Should installation on the right be required, the direction of the bar’s opening must be inverted.
ENGLISH Bar fitting intermediate plate Bar fitting cover - Insert the bar in the fitting cover and secure it with screws. UNI5931 M8x20 UNI5931 M8x12 - Measure the length of the bar, cut the bar slot to the same length. - Insert it in the bar’s conduit, a procedure that should be carried out on both sides. Insert the shock-resistant profile and cut excess length. Lastly, secure the bar end plug with the screws provided. UNI6954 Ø2.
ENGLISH The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici S.p.A. - Tighten the anti-shearing protection cover to the bar fitting with UNI6954 Ø3.9x19 screws. UNI6954 Ø3.9x19x12 5.6 Bar balancing - Prior to bar balancing, select a suitable spring depending on the situation at hand. See table below. 400 mm PASSAGE CLEARANCE LAMP (max. 7.
- Insert the UNI5739 M12X70 screw into the spring securing bracket and tighten the UNI5588 M12 nut to the screw (1-2). Tighten the screw to spring (2) and the tie rod to the part underneath (3-4). - Hook the tie rod to the anchoring racket. Perform the same procedure if there is a second screw. 10 The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici S.p.A.
- Release the gearmotor and manually turn the spring to increase or decrease traction until the bar rests at 45°. ENGLISH The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici S.p.A. - Tighten the blocking nut and refasten the gearmotor.
5.8 End stop adjustment - Execute the closing operation, adjust the open bar’s position by turning the free damper clockwise (to increase the bar’s run) or counter-clockwise (to decrease the run). Adjustment of the position with a ~89° aperture from the closed position is recommended. ^ ^ - The procedure is similar for the bar’s opening position. Adjust the closure damper screw until a position parallel to the road surface is reached.
ENGLISH , - After making adjustments and settings from the control panel, put the container lid in place and secure with screws. : The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici S.p.A. - After bar opening and closing adjustment, tighten the locking nuts under the dampers. -…place back the inspection door (1) and the upper dome (2). - Lock the door with the key.
5.9 Manual release of the barrier - Manually raise the bar and block it again by turning the key counterclockwise. 6 Maintenance 6.1 Periodic maintenance The unit does not require specific maintenance. Only as a precautionary measure and in case of intensive use, we recommend periodic checks (every 6 months) on the state of the electric wire connected to the motor, the spring-bar balance, the tightness of the nuts and the proper oiling of the sliding points between fixed and mobile parts.
In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certified in compliance with the UNI EN ISO 14001 standard to ensure environmental protection. Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal: DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.
CAME UNITED KINGDOM LTD UNIT 3, ORCHARD BUSINESS PARK TOWN STREET, SANDIACRE NOTTINGHAM - NG10 5BP - U.K. Tel 0044 115 9210430 Cod. 119GT41 ver. 1.