AUTOMATION FOR SECTIONAL AND OVERHEAD GARAGE DOORS VER SERIES INSTALLATION MANUAL V900E
“IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS” ENGLISH This symbol indicates sections to be read with particular care. This symbol indicates sections concernig safety. This symbol indicates notes to communicate to users. 2 Destination and limits of use 2.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. ENGLISH TRANSMISSION GUIDES V0679 – Chain guide unit L=3.02 m V0684 – the same as the V0679 but two parts need assembling - counterweighted overhead doors up to 2.40 m in height; - Spring balanced overhead doors up to 2.25 m in height; - sectional doors* up to 2.20 m in height. V0682 – Chain guide unit L=3.
.4 Dimensions MM MM MIN ¿ MM MAX 5 Installation The installation must be carried out by export, qualified personnel in total compliance with the norms in effect. 5.
.3 Cable list and minimum thickness Connections Type of cable Length of cable 1 < 10 m L. of cable 10 < 20 m L. of cable 20 < 30 m 230V power supply FROR CEI 20-22 CEI EN 50267-2-1 Photocell transmitters Photocell receivers 24V power supply to accessories Control and safety devices Antenna connection 3G x 2,5 mm2 3G x 4 mm2 2 x 0,5 mm2 2 x 1 mm2 2 x 1,5 mm2 2 x 0,5 mm2 2 x 0.
5.5 Preparing the transmission guide ENGLISH 1) Fasten the bracket to the tension device on the transmission guide using the supplied bolts and washers. M6 M6 x 20 ¿ MM ¿ MM 2) Position the transmission guide in the following manner: - for sectional doors directly above spring-release coiling shaft (between 20 and 30 mm of the shaft’s axis). N.B.
5.6 Fastening the transmission guide ENGLISH The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. 1) Fasten the transmission guide to the centre of the doorway using the proper screws. Raise the guide until it is horizontal with the ceiling so as to choose the proper type of fastener.
5.7 Fastening the guide arm to the transmission guide 2) Release the traction slide by turning the small level clockwise. Move the slide towards the door and hook it onto the guide arm with the supplied bolt. UNI 5739 M6 x 20 8 The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
5.8 Fastening the gearmotor to the transmission guide ENGLISH The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. 1) Remove the cover of the motor unit. UNI 6954 ø 3.9 x 13 2) Fasten the motor unit to guide’s support racket using the three screws supplied with the kit. N.B.: if needed, the unit may be fasten in the other three perpendicular positions, as per the drawings.
6 Electronic control panel The control panel is powered by 230V on the L-N terminals, with a 50/60 Hz frequency. The command devices and accessories run on 24V. Moreover, the total accessories cannot run on more than 40W. The panel controls a service light to light up the service area; at each opening it lights up for 2 minutes and 30 seconds. The V0670 card may be connected to operate the automation kit with emergency batteries (see the technical documentation attached).
Warning! Before doing any work on the automation kit, cut off the pwer supplì and disconnect the emergency batteries (if connected). 2 3 4 6 6 19 18 # "/!2$ &53% M! & 1) Line fuse 1.6A 2) Emergency batteries’ slot 3) Gearmotor 4) Transformer 5) Transformer connection terminal board 6) Motor fuse 7.5A 7) Gearmotor connection terminal board 8) Encoder connection terminal board 9) Signal Led for radio-code and encoder programming 10) Radio-code save button 11) SLOW.
6 6 Gearmotor 24V d.c. with encoder Transformer Command and safety devices If a button is connected, then remove the fuse-bridge. % # Stop button (N.C. contact) - Stops movement, excludes the automatic closing functions. To restart the automated kit, press a command button or a remote control button. Key and/or push button selector switch (N.O. contact) - Opening and closing devices.
Warning devices % # ENGLISH Movement Flasher (contact capacity: 24V – 25W max.) Flashes during the opening and closing phases. # "/!2$ &53% M! & 6.4 Function selection 3,/7 3%.3 #, 3%.3 ! # 4 /0 3%.3 /0 #, /0%. %.# 2!$)/ /. !## &53% ! & 6 6 6 % - . /. ON :, ,).% &53% ! & -/4/2 &53% ! & , 4 , 4 , !& OFF . 1 ON – Encoder programming - activates the opening and closing end-stops adjustment procedure. 2 deactivated.
7 Programming the end-stops IMPORTANT: before performing any programming, read the instructions carefully. Carry out the following instructions in the proper order otherwise the programming will fail. ENGLISH - Release the automation and position the door in the fully opened position. - When the door is fully opened, fasten the mechanical stop to the traction slide. Mechancal stop Slide guide - Manually close the door until the release is locked into place again.
...then briefly press the ENC/RADIO button (if the signal led stays on for some seconds and then starts flashing again, the programming operation is satisfactorily complete). 3,/7 3%.3 ! # 4 #, 3%.3 /0 3%.3 /0 #, %.# 2!$)/ /0%. 3,/7 3%.3 6 6 6 - . % !## &53% ! & /0 3%.3 /0 #, /0%. %.# 2!$)/ 6 6 6 - . % :, :, ,).% &53% ! & #, 3%.3 ,).
8 Activating the remote control Radiofrequecy card Only for highlighted cards. Position the jumper as show in the illustration depending on the series of transmitters used (see figure). TOP Frequency/MHz Radiofrequency card Series of transmitters FM 26.995 AF130 TFM FM 30.900 AF150 TFM AM 26.995 AF26 TOP AM 30.900 AF30 TOP AM 433.92 AF43S / AF43SM TAM / TOP AM 433.92 AF43SR ATOMO AM 40.
Transmitters TOP T432M - T312M D 0 ENGLISH The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. TOP SERIES 0 Input the code into the C selector and set the channel on D (P1 = CH1 and P2 = CH2: default setting) P1 /. CH1 0 0 0 CH2 CH4 /. /.
QUARZ TOP SERIES ENGLISH 1 note down the selected code (for future need) 0 /&& 0 /. 2 insert the J coding jumper to activate the procedure 3 memorise the code, pressing P1 and/or P2 in the above sequence. At the end, a double sound will confirm the memorisation. 4 remove the J jumper 0 TOP T262M - T302M 0 The first coding must be made leaving the C jumpers in the position shown in fig A. For any other coding operations on other channels position the C jumpers as shown in fig. B. FIG.
T2622M - T3022M T264M - T304M P2 = CH2 0 0 1° Code 0 0 P1 = CH1 ENGLISH P2 = CH2 P3 = CH3 P4 = CH4 0 0 0 0 0 /&& 0 /. 2° Code P3 = CH1 P4 = CH2 Memorisation # "/!2$ &53% M! & 1) Keep the ENC/RADIO pressed on the circuit board. The led indicator will flash. 3,/7 3%.3 ! # 4 #, 3%.3 /0 3%.3 /0 #, /0%. %.# 2!$)/ !## &53% ! & 6 6 6 - . % LED flash :, ,).% &53% ! & -/4/2 &53% ! & , 4 , 4 , ENC/RADIO /. !& .
9 Maintenance The unit does not require specific maintenance. Only as a precautionary measure and in case of intensive use, we recommend periodically checking (every 6 months) on the state of the electric wire connected to the motor, that the chain and belt tension is right, the tightness of the nuts and the proper oiling of the sliding points between fixed and mobile parts. All checks must be recorded (in a dedicated record-book). 9.