Manual

TX320 Transmitter
7.6.5.6 P127, Command 5: Clear TX320 Error Registers
Clear error registers of TX320. Requires one input location.
TABLE 7-11. P127 Command 5: Clear Error Registers
In Loc Contents
1 Result Code
Result code of 0 indicates success. Command 5 is used to erase all errors from
the error registers of the TX320.
7.6.5.7 P127, Command 6: Return TX320 to Online Mode
Command 6 is used to return the TX320 to online mode. Typically used after a
forced random transmission. The TX320 has an offline time-out of one hour.
TABLE 7-12. P127 Command 6: Force Online Mode
In Loc Contents
1 Result code
Result code of 0 indicates success.
7.6.6 Edlog Programming Examples
Edlog Instruction 126 is used to copy data from the datalogger final storage
area to the TX320 data buffer.
Edlog program example 1 writes data to final storage once an hour and
transfers data to the TX320 once every 4 hours.
; Edlog Program Example 1
; Set output flag high hourly
1: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
; Write a time stamp to final storage
2: Real Time (P77)
1: 1221 Year,Day,Hour/Minute,Seconds (midnight = 2400)
; Write 41 input locations to final storage
3: Sample (P70)
1: 41 Reps
2: 1 Loc [ Status_RC ]
; Check if top of 4 hour interval, if true execute P126
33