Manual

TX320 Transmitter
does not respond with the ACK character within 500 ms after the data has been
transferred, the result code is 7. Result code 7 indicates the data was not
received by the transmitter. The datalogger cannot resend the data.
The GoesData() and GoesSetup() instructions may also have a negative result
code (see TABLE 8-2). A negative result code indicates that there is an illegal
value in one of the parameters.
TABLE 8-1. Result Codes Indicating Communication Problems
0 Command executed successfully
2 Time out waiting for STX character after SDC addressing
3 Wrong character (not STX) received after SDC Addressing
4
Something other than ACK returned when select data buffer command
executed
5 Timed out waiting for an ACK when data buffer command was sent
6 CS I/O port not available, port busy
7 ACK not returned following data append or insert command
TABLE 8-2. GoesSetup and GoesData Runtime Result Codes
Code Error Condition
-11 Illegal Buffer Control
-12 Illegal Message Window
-13 Illegal Channel Number
-14 Illegal Baud Rate
-15 R count Error
-16 Illegal Data Format
-17 Illegal Data Format FP2_ASCII
-18 Self-Timed Interval Error
-19 Self-Timed Offset Error
-20 Random Interval Error
-21 Platform ID Error
8.3 Error Codes
Error codes are stored in variables or input locations by using command 4 in
CRBasic's GoesStatus() instruction or Edlog's Instruction 127 (see Section
7.5.2, GoesStatus(), and Section 7.6.5, Read Status and Diagnostic Information
from the TX320). TABLE 8-3 lists the possible error codes.
35