Manual

Appendix F. Extended ASCII Command Set
F-16
F.5.8 Read Reflected Power
Syntax:
RRFL
Access level: USER
TX320 State: Enabled/Disabled
Returns the reflected power in dBm. This value is updated at the bit rate when
transmitting and every 30 seconds when not transmitting.
F.5.9 Read Power Supply
Syntax:
RPS
Access level: USER
TX320 State: Enabled/Disabled
Returns the power supply voltage in volts. This value is updated at the bit rate
when transmitting and every 30 seconds when not transmitting.
F.5.10 Read TCXO Temperature
Syntax:
RTEMP
Access level: USER
TX320 State: Enabled/Disabled
Returns the TCXO temperature (PCB temperature) in degrees C. This value is
updated at the bit rate when transmitting and every 30 seconds when not
transmitting.
F.5.11 Read Measured Frequency
Syntax:
RMF
Access level: TECHNICIAN
TX320 State: Enabled/Disabled
This command returns the last measured OCXO and TCXO frequencies in the
following format:
F-OCXO: 10000005.9000
F-TCXO: 43199.9166
Units are Hz.