Programming instructions

16
You cannot cancel or undo a Power Block cloning.
To clone a Power Block
1. In the main window, click Configuration and then Ventilation.
2. Below Your Power Blocks, select the Power Block you want to configure and then click Configure
Power Block.
The Power Block configuration window displays.
3. Click Clone Power Block.
The Power Block cloning window displays.
4. Select the Power Block you want to copy.
5. Click OK to copy the configuration and return to the Power Block configuration window.
Enabling additional probes, deicing, and rain detection
If you are configuring PBx Power Blocks, you have the option to configure additional probes, actuator
deicing, and rain detection.
PBx-10 temperature probes
The PBx-10 has four temperature probe terminals, with the ability to average temperatures of all
connected probes to provide a more balanced reading. By default, only probe 1 is enabled.