Programming instructions

42
To program the temperature setback
1. In the main window, click Settings, and then Ventilation.
2. Below Your Power Blocks, select the Power Block you want to program and then click Edit
setbacks.
The Temperature setbacks window displays.
3. Adjust the DIF settings.
To enable or disable the setback, select DIF enabled. There is a checkmark in the box when it
is enabled.
To change the setback amount, beside Setback, type a number in the box or click Up or
Down.
To change the start or stop time, click and drag the number for the hour or minute up or
down. You can also click the number and then press UP or DOWN on your keyboard.
4. Click OK to save the changes and return to the Settings window.
Programming alarms
You can program alarms that notify you of communication errors and undesirable temperature
conditions. When there is an alarm condition, the Power Block alarm relay immediately activates,
and Select Ventilation posts a message in the Communication Center and Alarm log.
Communication errors
For each Power Block, you have the option to enable communication alarms or warnings.
Communication errors occur when an active Power Block becomes unresponsive.
Communication alarms
When you enable communication alarms and there is a communication error, OMNI Select displays
a red "X" in the Communication Center. If you have Select Alert, the program dials out.
Communication warnings
When you enable communication warnings and there is a communication error, OMNI Select
displays a yellow "!" in the Communication Center. If you have Select Alert, the program does not dial
out.