Programming instructions

58
C This is the set point for the selected relay.
To adjust the set point, click and drag its slider up or down.
To adjust the set point by 0.1-degree or 1 percent increments, click the slider and then press
UP or DOWN on your keyboard.
To adjust the set point by 1.0-degree or 10 percent increments, click the slider and then
press PGUP or PGDOWN.
D These are the duty cycle settings. Duty cycle settings display only if the duty cycle is enabled.
To adjust a duration, click and drag the number up or down.
To adjust a duration by 1 minute or 1 second increments, click the number and then press
UP or DOWN on your keyboard.
To adjust a duration by 10 minutes or 10 second increments, click the number and then
press PGUP or PGDOWN.
After the room is properly set up and balanced, you should not need to change
the relay settings. Changing the settings after the room is set up can affect the
ventilation balance in the room. If you need to change settings after the room is
set up, you should change the Power Block settings. For more information, read
Programming Power Block settings on page 31.
If the Power Block is in empty room mode:
Cooling equipment – no relay settings are available and equipment does not
operate.
Heating equipment – all settings are available. Equipment operates only if needed
to keep the temperature at or above the set point.
Use the Heating and cooling elements worksheet on page 88 when programming
relays.
To program single-stage heating and cooling relays
1. In the main window, click Settings, and then Ventilation.
2. Below Your Power Blocks, select the Power Block you want to program and then click Edit
settings.
The Ventilation settings window displays.
3. Below Equipment settings, click Stages.
The window displays the relay settings.
4. If the relay you want to program is not selected, beside Relay, select the one you want.