Programming instructions

82
Master settings worksheet
Enter your Power Block settings in the table below.
Use the information in the table to program your master settings in Select Ventilation.
Configuration and information
Name Address
Building Type
Master set point
Master set point This is the target temperature.
Growth curves
Enabled? Set point
Master set point curve Yes No
There are too many details to show curve settings here.
VAR 1 min ventilation Yes No
VAR 2 min ventilation Yes No
VAR 3 min ventilation Yes No
VAR 4 min ventilation Yes No
Alarm settings
Low temperature
The lowest temperature to which you can safely allow the zone to
fall; cannot be higher than high alarm temperature
High temperature
The highest temperature to which you can safely allow the zone to
rise; cannot be lower than low alarm temperature
Bias offset
The number of degrees to add to the high alarm temperature when
the outdoor temperature is higher than the alarm temperature.
High alarm maximum
The highest temperature to which you can safely allow the zone to
rise; cannot be lower than high alarm temperature
Temperature setback
Enabled? Start time Stop time Setback
DIF Yes No : :
Power save Yes No : :
Temperature in °F/°C, range: 14.0 to 122.0°F, –10.0 to 50.0°C
Temperature in °F/°C, range: 0.0 to 25.0°F, 0.0 to 14.0°C
Temperature in °F/°C, range: 0.0 to 20.0°F, 0.0 to 11.1°C