Service Manual

Table Of Contents
Canon NEW F-1 Service manual
Page 35
Disassembly
1. The mounting screw (7}-l for Mg2
is hidden under the lead solder
connection.
2. Mg2 Lead is a single solid, lead.
Take care not to kink the cable.
Assembly and Adjustment Notes
1. Lower body Flex
Apply Tuffy TF-1156 to the MD
Contacts on the lower flex as
shown.
1) MD contact Assembly (Back
side)
2) MD Contacts (Front side)
1.1 Don't forget washer (6)-2. 2.
2. Mg2
2.1 The Mg2 latch lever should have
0.3 to 0.5mm overcharge
2.2 Adjust the overcharge by bending
charge lever (10).
Assembly and Adjustment Notes
3. The shorter hook of the main diaphragm
charge lever spring (11)-2 hooks at the
diaphragm release drive lever (Matsuba
lever) -which is part of the diaphragm
charge lever (11).
4. Winding Stopper Levers
4.1 Assemble the stopper charge lever (17)
and the winding stopper (16) and
mount them on the shaft.
4.2 Onto them install spring (15) and
charge lever (15).
Note: Numbers in parentheses in the text
correspond to circled numbers page
34.Disassemble in normal order and
reassemble in reverse order.