- Excalibur Indoor Fireplace User Manual

Excalibur
®
P90 Zero Clearance Direct Vent Gas Fireplace 11
VENTING
FPI Direct Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with the P90 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent
Termination Locations" section.
FPI Direct Vent (Flex) System Termination
Kit (Part # 946-515) includes all the parts
needed to install the P90 with a maximum
run of 4 feet.
1) 6-7/8" dia. fl exible liner (4 ft. length)
2) 4" dia. fl exible liner (4 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
If a longer run is needed, the FPI Direct Vent
system (Flex) kit is 946-516 which includes
all the parts needed to install the P90 with a
maximum 10' run.
1) 6-7/8" dia. fl exible liner (10 ft. length)
2) 4" dia. fl exible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless Steel
(4)
Notes:
1) Liner sections should be
continuous without any joints or
seams.
2) Only Flex pipe purchased from FPI may
be used for Flex installations.
3) Horizontal vent must be supported every
3 feet.
INSTALLATION