- Excalibur Indoor Fireplace User Manual

Excalibur
®
P90 Zero Clearance Direct Vent Gas Fireplace
4
This is a copy of the label that accompanies each
P90 Zero Clearance Direct Vent Gas Fireplace.
We have printed a copy of the contents here for
your review. The safety label is located on the
front inside base of the unit, visible when the
bottom louver is open.
NOTE: Excalibur
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
SAFETY LABEL
Copy of Safety Decal for P90
APPAREIL FONCTIONNANT AU GAZ PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit minimum selon
D bit maximum selon
Modéle P90-LP1
ééé
é
é
é
l'altitude
Calorifique
Calorifique
l'altitude
Grandeur de l'injecteur
D bit Calorifique minimum selon
D bit Calorifique maximum selon
é
é
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
309
NATURAL GAS:
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
Model P90-NG1
L
PROPANE:
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Altitude
Orifice size
Minimum input
Maximum input
High
Model P90-LP1
L
Altitude
Orifice size
Minimum input
Maximum input
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles
/Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Mantel Clearances from Top:
Side Wall Clearance
from Side Facing
Top, bottom, sides & rear of unit
Min. 18-1/4" (464mm)
6-1/2" (165mm)
Minimum Vent Clearances:
Horizontal Top 2-1/2" (64mm)
Horizontal Side
Horizontal Bottom 1-1/2" (38mm)
1-1/2" (38mm)
Alcove Clearances:
Max. Depth 36" (914mm)
Min. Width 48" (1219mm),
Min. Height 72" (1229mm)
Serial No./ No de serie
918--503
5" WC(1.25 kPa)
3.8" WC(0.95 kPa)
1.1" WC(0.27 kPa)
# 34 DMS
18,200 Btu/h (5.42 kW)
0-4500 ft/pi (0-1372 m)
35,000 B (10.26 )tu/h kW
12" WC(3.00 kPa)
11" WC(2.74 kPa)
2.9" WC(0.72 kPa)
# 51 DMS
17,950 Btu/h (5.26 kW)
35,000 B (10.26 )
0-2000 ft/pi (0-610 m)
tu/h kW
2000-4500 ft/pi (610-1372 m)
# 52 DMS
15,500 Btu/h (4.54 kW)
31,000 Btu/h (9.08 kW)
APPAREIL FONCTIONNANT AU NATURAL GAZ
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit minimum selon
D bit maximum selon
l'altitude
Modéle P90-NG1
ééé
é
é
é
Calorifique
Calorifique
VENTING: This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or
the current CAN 1-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation
instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations,
Sites, and Communities ANSI /NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada. Optional Fan (Part # 432-917) Optional Heat Wave Kit # 946-556
Optional Heat Release Kit # 946-570. Electrical supply 115VAC, 1.13A, 60Hz.
Not for use with solid fuel. This vented gas fireplace is not for use with filters. For horizontal runs exceeding 10’, 5” x 8” piping must be used.
MAY BE INSTALLED IN MANUFACTURED (MOBILE)
HOMES AFTER FIRST SALE.
Listed:
Certified for/Certifi e pour:
Tested to:
Report No.
VENTED GAS FIREPLACE HEATER
CANADA and U.S.A.
Gas-Fired Appliances For Use At High Altitudes
476-3059100 (June 2004)
é
CAN/CGA-2.17-M91,
Vented Gas Fireplace Heaters ANSI Z21.88b-2003/CSA 2.33b-2003
Made in Canada/ Fabrique au Canada
Duplicate S/N
(See Instruction Manual for
Detailed Instructions)
Model/Modele:
P90-NG1
Model/Modele:
P90-LP1
309
6-1/2"
6-1/2"
Wa
ll
Wa
ll
18-1/4"
44-1/4" To Ceiling
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.