Connecting Power
Connecting Chassis to Ground
To connect the EdgeFLEX 600 chassis to ground, perform the following steps:
1. Slide the attached Panduit ground lug onto an appropriate ground wire (8 AWG), and crimp
securely.
2. Place the ground lug over the two posts in the lower left corner of the rear of the chassis as
shown below.
3. Fasten the two locking nuts securely onto each post.