User's Manual

EdgeFLEX 600 - Release 2.0 3-9
Adding and Replacing Components
Nonreplaceable Components
4. At this point, be sure the ejector latch is perpendicular to the card (in the ejected position), then
gently press the ejector latch toward the card. The ejector latch should engage with the chassis
and draw the card into its fully-inserted position. Use a smooth, quick action to install the card
so that electrical connections from the card to the backplane are made at once. When the card
is fully inserted, the ejector latch will snap into its locked position.
If you feel more than a slight amount of resistance, STOP and recheck that the card is correctly
aligned with the chassis guides.
5. After inserting the card fully, use a #2 Phillips screwdriver to tighten the captive thumbscrews
at the right and left sides of the card by turning clockwise until secure.
Nonreplaceable Components
The fan tray assemblies, air filter, Management Card, SCPX cards, service cards, Power Supply Units,
OMT modules and SFP modules are the only user-replaceable components of the EdgeFLEX 600
chassis.
If you suspect any other component of the EdgeFLEX 600 to be faulty, contact your Carrier Access
representative.