Table 2A Physical Data; 30HL, HWA Condenserless Units English
UNIT 30 HWA018 HWA025 HWA028 HWA035 HWA040 HL050 HL060
OPERATING WT (Approximate) lb 740 880 960 975 1080
2070/
2120*
2130/
2190*
REFRIGERANT† lb R-22
1.6 2.0 2.4 2.4 3.0 6.3/4.2** 5.3/5.3**
COMPRESSOR
Model No. 06DG537 06E2250 06E7265 06E7275 06E7299
06E6275,
06E2250
06E6275
Nominal Hp 15 20 25 30 35 25,20 30 (ea)
Quantity 111111(ea) 2
Cylinders Per Compressor 646666,4 6
Capacity Control Standard
No. of Steps 32333 4 4
Minimum Step Capacity (%) 33 50 33 33 33 20†† 33
Capacity Control With Optional
Hot Gas Bypass
No. of Steps 43444 5 5
Minimum Step Capacity (%) 10 10 10 10 10 10 10
Relief Valve Flow Rate lb air/min 15.1 15.1 15.1 15.1 15.1 15.1
COOLER
Part No. LL01SB006 LL01SB007 LL01SB009 LL01SB009 LL01SC005 10HA400654 10HA400664
Dry Weight lb 69 81 105 105 145 726 726
Fluid Side psig 300 300 300 300 300 150 150
Refrigerant Side psig 430 430 430 430 430 235 235
Net Fluid Volume Gal. 1.4 1.6 2.1 2.1 3.3 13.1 15.2
(includes nozzles)
Fluid Connections in. Grooved End
Inlet 1
1
2
1
1
2
1
1
2
1
1
2
2
1
2
33
Outlet 1
1
2
1
1
2
1
1
2
1
1
2
2
1
2
33
CONDENSER CONNECTIONS
Refrigerant Connections in.
Liquid Line ODS
7
8
7
8
7
8
7
8
7
8
7
8
7
8
Discharge Line ODS 1
1
8
1
1
8
1
3
8
1
3
8
1
5
8
1
3
8
1
3
8
LEGEND
ODS Outside Diameter, Sweat
*60 Hz/50 Hz units.
†30HWA and HL units (condenserless) are shipped with a refrigerant holding
charge. Approximate cooler operating charge is shown.
**Ckt 1/Ckt 2.
††With transfer switch set to compressor no. 2 position; 40% with transfer switch
set to compressor no. 1 position.
NOTE: Operating weight includes refrigerant operating charge and weight of
fluid in the heat exchangers.
Table 2B Physical Data; 30HL, HWA Condenserless Units SI
UNIT 30 HWA018 HWA025 HWA028 HWA035 HWA040 HL050 HL060
OPERATING WT (Approximate) kg 335 399 435 442 490
938/
961†
966/
993†
REFRIGERANT† kg R-22
0.7 0.9 1.1 1.1 1.4 2.9/1.9** 2.4/2.4**
COMPRESSOR
Model No. 06DG537 06E2250 06E7265 06E7275 06E7299
06E6275,
06E2250
06E6175
Nominal kW 11.2 14.9 18.7 22.4 26.1 18.7,14.9 22.4 (ea)
Quantity 111111(ea) 2
Cylinders Per Compressor 646666,4 6
Capacity Control Standard
No. of Steps 32333 4 4
Minimum Step Capacity (%) 33 50 33 33 33 20†† 33
Capacity Control With Optional Hot Gas Bypass
No. of Steps 43444 5 5
Minimum Step Capacity (%) 10 10 10 10 10 10 10
Relief Valve Flow Rate kg air/min 6.8 6.8 6.8 6.8 6.8 6.8
COOLER
Part No. LL01SB006 LL01SB007 LL01SB009 LL01SB009 LL01SC005 10HA400654 10HA400664
Dry Weight kg 31.3 36.7 47.6 47.6 65.7 330 330
Fluid Side kPa 2069 2069 2069 2069 2069 1034 1034
Refrigerant Side kPa 2965 2965 2965 2965 2965 1620 1620
Net Fluid Volume L 5.3 6.1 8.0 8.0 12.5 49.9 57.5
(includes nozzles)
Fluid Connections in. Grooved End
Inlet 1
1
2
1
1
2
1
1
2
1
1
2
2
1
2
33
Outlet 1
1
2
1
1
2
1
1
2
1
1
2
2
1
2
33
CONDENSER CONNECTIONS
Refrigerant Connections in.
Liquid Line ODS
7
8
7
8
7
8
7
8
7
8
Discharge Line ODS 1
1
8
1
3
8
1
5
8
1
3
8
1
3
8
LEGEND
ODS Outside Diameter, Sweat
*60 Hz/50 Hz units.
†30HWA and HL units (condenserless) are shipped with a refrigerant holding
charge. Approximate cooler operating charge is shown.
**Ckt 1/Ckt 2.
††With transfer switch set to compressor no. 2 position; 40% with transfer switch
set to compressor no. 1 position.
NOTE: Operating weight includes refrigerant operating charge and weight of
fluid in the heat exchangers.
12