Product data

Options and accessories
ITEM OPTION* ACCESSORY†
Shipped Factory Charged with Refrigerant X
Shipped Factory Charged with Nitrogen X
One, 2, or 3 Pass Cooler or Condenser Waterside Construction X
Full Insulation (except waterbox covers) X
Refrigerant Isolation Package XX
Waterbox Options (Frame 4 Machines Only):
300 psig (2068 kPa) Nozzle-in-Head Waterboxes X
300 psig (2068 kPa) Marine Waterboxes X
300 psig Flanged Cooler and/or Condenser Waterbox Nozzles X
Automatic Electric Hot Gas Bypass XX
Unit-Mounted Wye-Delta or Solid-State Low Voltage Starter XX
Remote Motor Wye-Delta or Solid-State Low Voltage Starter X
Control Options Module X
.028- or .035-in. Internally/Externally Enhanced Copper Tubing
Cooler/Condenser
X
.028- or .035-in. Smooth Bore/Externally Enhanced Copper Tubing
Cooler/Condenser
X
.028- or .035-in. Smooth Bore/Externally Enhanced Cupronickel Tubing
Condenser
X
.028- or .035-in. Internally/Externally Enhanced Cupronickel Tubing
Condenser
X
.025- or .028-in. Wall Tubes, Internally Enhanced Condenser X
.025- or .028-in. Wall Tubes, Titanium, Smooth Bore, Condenser X
Factory Performance Test X
Export Crating X
Extended Warranty (NAO [North American Operations] Only) X
Service Contract X
Acoustical Sound Insulation Kit X
Field Mounting Kit (Unit-Mounted Starters) X
Storage Tank and Pumpout Unit X
Stand Alone Pumpout Unit X
Soleplate Package X
Spring Isolators X
Spare Sensor Package X
Control Options Module Upgrade Kit X
Flow Switch, Differential Pressure Type X
*Factory Installed.
†Field Installed.
UNIT-MOUNTED STARTER FEATURES AND OPTIONS
ITEM WYE-DELTA SOLID STATE
NEMA 1 Enclosure with Integral Fan Cooling and Lockable
Hinged Doors
SS
Carrier Starter Management Module and 5 Pilot Relays SS
1 kVa Controls/Oil Heater Transformer with Branch Circuit Breaker SS
Microprocessor Based Overload Trip Protection S* S
Main Power Disconnect (Non-Fused Type) with Shunt Trip S N/A
Normal Interrupt Capacity Main Circuit Breaker with Shunt Trip OS
High Interrupt Capacity Main Circuit Breaker with Shunt Trip OO
Phase Loss/Reversal Imbalance Protection S* S
Ground Fault Protection S* S
Integral SCR Bypass Contactor N/A S
Three-Phase Digital Ammeter S* S
Three-Phase Analog Ammeter with Switch OO
Three-Phase Digital Voltmeter O† S
Three-Phase Analog Voltmeter with Switch OO
Three-Phase Over/Under Voltage Protection O† S
Power Factor Digital Meter O† S
Frequency Digital Meter O† S
Digital Watt Meter O† N/A
Digital Watt Hour Meter O† N/A
Digital Power Factor Meter O† N/A
Digital Watt Demand Meter O† N/A
Digital Var Meter O† N/A
IQ Data Plus II O† N/A
Lightning Arrestor and Surge Capacitor Package OO
Kilowatt Transducer with 4 to 20 mA Output OO
Power Factor Correction Capacitors OO
LEGEND
N/A Not Applicable
NEMA National Electrical
Manufacturers
Association
S—Standard Feature
SCR Silicon Control Rectifier
O—Optional
Var Volts Amperes Reactive
(Reactive Power)
*Included in the Standard IQ 1000 II™
Motor Protection system.
†Requires IQ Data Plus II™ system.
10