Installation manual

38GL_MG / 38YY(S)_MG
R-410A
GB - 2
Dimensions and weight
Dimensions and weight
38GL2M12G
38GL4M24G
38YY2M21G
38YY2M24G
38GL2M18G
38GL2M24G
38GL3M21G
38YY2M18G
38GL2M36G
38GL2M48G
38YY(S)2M36G
38YY(S)2M48G
Heat Hi-Wall Console Cassette Satellite
pump Power supply
models 42PHQ-N 42HMC-N 42VMC-N 40KMC-N 40SMC-N
38YY2M18G 009 009 009 - 009
38YY2M21G 009 - 012 009 - 012 009 - 012 012 009 - 012
38YY2M24G 012 012 012 012 012 230V ~ 50Hz
38YY(S)2M36G 018 018 018 018 018
38YY(S)2M48G 024 024 024 024 024
EED
EED
EED
B
C
F
Ø 8,5
C
F
Ø 8,5
C
F
Ø 8,5
A
B
A
A
B
EED
C
F
A
B
Note
(1)
: These models can also be connected to the following units: 42PHW, 42HWS, 42HMC, 42VKG-W, 42VMC, 40GKX and 40JX
Cooling Hi-Wall Console Cassette Satellite
only Power supply
models 42PHQ-N 42HMC-N 42VMC-N 40KMC-N 40SMC-N
38GL2M12G
(1)
009 - 012 009 - 012 009 - 012 012 009 - 012
38GL2M18G
(1)
009 009 009 - 009
38GL2M24G
(1)
012 012 012 012 012
38GL2M36G 018 018 018 018 018
230V ~ 50Hz
38GL2M48G 024 024 024 024 024
38GL3M21G
(1)
009 - 012 009 - 012 009 - 012 012 009 - 012
38GL4M24G 009 - 012 009 - 012 009 - 012 012 009 - 012
Table I
Cooling only
models
38GL2M12G 38GL2M18G 38GL2M24G 38GL3M21G 38GL4M24G 38GL2M36G 38GL2M48G
A mm 660 800 800 800 800 800 800
B mm 504 590 590 590 803 1264 1264
C mm 220 300 300 300 300 300 300
D mm 390 508 508 508 508 508 508
E mm 135 146 146 146 146 146 146
F mm 250 330 330 330 330 330 330
kg
kg 39 55 58 58 69 109 112
Heat pump
models
38YY(S)2M36G 38YY(S)2M48G 38YY2M18G 38YY2M21G 38YY2M24G
A mm 800 800 800 800 800
B mm 1264 1264 590 803 803
C mm 300 300 300 300 300
D mm 508 508 508 508 508
E mm 146 146 146 146 146
F mm 330 330 330 330 330
kg
kg 112 119 59 69 71