User guide

Table 3 — Heater Assemblies
Table 6 — Casing Dimensions (in)
HEATER
ASSEMBLY
(See Table 1)
KILOWATTS
PRIMARY
LS
(F)
SECONDARY
LS
(F)
VI
1.6 140 200
V2
2.8
140 200
V3
4.5 140 200
V4
5.0
140 210
LS — Limit Switch
Table 4 — Thermistor
KEY NUMBER
CARRIER VENDOR
RESISTANCE
(See Table 1)
NUMBER NUMBER (Ohms)
Z-1
42320001
CM305C20C
25
Table 5 — Capacitor
KEY NUMBER
(See Table 1)
CARRIER
NUMBER
MFD
VOLTS
RC-1
05706028
25/5
370
RC-2
05706030 30/5
370
RC-3
05706031 45/5
370
KEY NUMBER
(See Table 1)
HEIGHT WIDTH DEPTH
305 16% 25% 6 23%4
405 17% 6 26 27% 6
Table 7 — Capillary Data
(See Table 1)
Length .002) ID (± .002)
CD-I
1 Tube — 47.0 1 Tube - .054
2 Tubes — 64 0 2 Tubes — 054
CD-2
2 Tubes — 29.3
2 Tubes — 054
1 Tube - 56 3
1 Tube - .064
CD-3
1 Tube — 47.0
1 Tube - .054
2 Tubes — 29.3 2 Tubes — 054
CD-4 1 Tube - 28 7
1 Tube — .064
CD-5
1 Tube - 39.5
1 Tube — .054
2 Tubes — 29.3
2 Tubes — .054
CD-6
2 Tubes — 40 5
2 Tubes — .054
Table 8 Capillary Insertion
DEPTH (In.)
DEPTH (in.)
(See Table 1)
Condenser Coll
Connection Tube
Evaporator Coil
Connection Tube
CI-1 1 1
Table 9 — Receptacles, Fuse Types, Wire Sizes
UNIT NAMEPLATE VOLTAGE 115
230/208
MAXIMUM NAMEPLATE AMPS
12
16
12
16
24
OUTLET RATED VOLTS/AMPS
125/15
125/20
250/15
250/20
250/30
RECEPTACLE CONFIGURATION
©
©
©
©
©
MFR PART NO.
Hubbell
P & S
GE
Arrow-Hart
5261
6201
GE5261-1
5261
5361
5361
GE4102-1
5361
5661
5661
GE4069-1
5661
5461
5871
GE4182-1
5861
9330
5930
GE4139-3
5700
TIME-DELAY FUSE OR CIRCUIT
BREAKER SIZE (AMPS)
FUSE TYPE
15
PI
20*
ug
15
20*
Cartridge
30
RECOMMENDED AWG
WIRE SIZEt
14 12
14
12
10
AWG — American Wire Gage
‘May be used for 15-amp applications if fused for 15-amp.
tBased on copper wire at 60 C temperature rating.