7. Carefully pull control box straight out from unit.
8. On right side and bottom of control box, manually dis
engage removable sheet metal panel to access control
box components. See Fig. 8. See Fig. 9 for control box
components.
9. Reverse above procedure for reassembly, taking care
not to pinch any wiring inside the control box. This is
accomplished by guiding the wiring from the rear of the
control as shown in Fig. 4.
Fig. 4 — Removing Control Box
SENSING
BULB
METAL
CLIP
BULB
HEATER
Fig. 7
BRAIDED
SLEEVE
SCREWS (2)
Removing Screws Securing Control Box
to Chassis
GRASP PANEL
Fig. 5 — Removing Knobs
Fig. 6 — Removing Escutcheon
LIFT PANEL
TO REMOVE
Fig. 8 - Removing Sheet Metal Panel