Owner`s manual

9

INSTALLING THE W-32 WALL CONTROL

2. Do not use any additional control with your Inteli-Touch
fan (for example, dimmer, or fan speed control).
3. Do not use more than one fan per wall control.
4. No other light fixtures or electrical appliances may be

control.

1. Remove the screws and switch plate from the existing switch box.
2. Remove the screws holding the switch in the switch box.
3. Pull the existing switch from the switch box to expose the wire
connections.
4. Remove the two wires from the switch.
 
control black wire and black/white stripe wire. Secure these connections
with wire nuts.
 
control to the ground wire in the switch box. Secure the splice with a
wire nut.
 
8. Install the wall plate with the two color-matched screws.
NOTE: If wall control operation is reversed (fan switch controls lights and
light switch controls fan) turn off the power at the breaker or fuse panel,
then swap the two W-32 black/white stripe wires.

is designed to signal the fan microcomputer as well as perform normal switching operations. For this reason the following
precautions must be observed:

To control the fan and lights from two locations (a three-way circuit), use two
W-32 wall controls.
1. Remove the screws and switch plate from the existing switch box and the screws
holding the switch in the switch box.
2. Pull the existing switch from the switch box to expose the wire connections.
3. Determine which wire is connected to the common terminal of the three-way switch.
(The terminal will be marked on switch).
4. Remove the wire from the common terminal of the three-way switch. Connect
this wire to the remaining black/white striped wire on the W-32 control. Secure
this splice with a wire nut.
5. Remove the two remaining wires from the three-way switch. Connect one
of these wires to a black wire on the W-32 control. Secure the splice with a
wire nut. The remaining wire is to be connected to the other black wire on the
W-32. Secure the splice with a wire nut.
6. Connect the green ground wire coming from the back of the W-32 control to
the ground wire in the switch box. Secure the splice with a wire nut.
7. Install the W-32 in the wall box with the two long screws provided.
8. Install the wall plate with the two short color-matched screws provided.
9. Installation of the second W-32 control is identical. Repeat steps 1 through 7.
NOTE: If wall control operation is reversed (fan switch controls lights and light
switch controls fan) turn off the power at the breaker or fuse panel, then swap
the two W-32 black/white striped wires.
R
R

Ensure power is turned OFF at the breaker or fuse panel before starting installation.

Ensure power is turned OFF at the breaker or fuse panel before starting installation.
R

In t e l I •to u c h
®